Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor ® hood assembly or Dacor raised vent must be purchased separately. See the hood or raised vent installation instructions to determine suitability. Part No. 65265 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 Safety Symbols and Labels.............................................. 1 General Safety Precautions.............................................. 2 Product Specifications...................................................... 3 Product Dimensions.......................................................... 3 Installation Planning and Preparation..........
Important Safety Instructions Important Information About Safety Instructions • The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. • Always contact the Dacor Customer Service Team about problems and conditions that you don’t understand. See Customer Service Information above.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, including the following: warning • • • Do not install or operate this unit if it has been damaged, dropped, has damaged electrical wiring or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
Product Specifications Product Dimensions All tolerances: +1/16”, -0, (1.6 mm,0) unless otherwise noted. 19" (483mm) 17 3/8" (441mm) 9 1/2" (241mm) 7 1/2" (191mm) CL Power Supply Conduit Hole CL 7 15/16" (202mm) 5 13/16" (148mm) 3 5/8" (92mm) 9 1/4" (235mm) 8" Nom.
Installation Planning and Preparation Electrical Supply Requirements Installation Planning • System Layout The power for this blower is supplied via 1/2” 3-wire wiring/conduit (not included) by an approved Dacor hood or raised vent. The wiring/conduit is installed between the hood or raised vent and the blower and shall be terminated on each end by a 1/2” UL certified strain relief. The power is turned on and off by the power switch on the approved ventilation device.
Installation Planning and Preparation Blower Location and Mounting (cont.) • Select a location that can properly support or can be reinforced to support the weight of the blower (see weight table below). The unit requires a mounting surface around the perimeter of the base of the unit 2” in width and thick enough to accommodate the 8, 2 1/2” long mounting screws that are provided with the unit. All contact surfaces between the blower and any mounting surfaces must be solid and at right angles.
Installation Instructions warning • If the electrical service provided does not meet the power requirements for the hood/raised vent and the blower combined, do not continue with the installation. Contact a licensed electrician to correct the situation before continuing. • Failure to connect the wiring as specified may result in an electric shock hazard and/or improper blower operation.
Installation Instructions Electrical Installation 7. Run the wiring used to supply power from the installed raised vent or hood to the blower parallel to the duct work. 8. Make sure that power to the raised vent or hood is disconnected or turned off at the circuit breaker or fuse box. 9. With the UL certified strain relief attached to the end of the wiring/conduit, feed the wires into the electrical access hole on the under side of the blower and attach it. 12.
Technical Data REMP Series Blower Ratings Model Number Nominal Rating* Actual Rating* REMP3 600 CFM 620.5 CFM REMP16 1000 CFM 994.8 CFM * At 0” static pressure REMP16 Blower Performance 5.0 Static pressure - inches of water Static pressure - inches of water REMP3 Blower Performance 4.0 3.0 2.0 1.0 0 100 200 300 400 500 600 Airflow CFM (Cubic feet/minute) 8 700 2.5 2.0 1.5 1.0 0.