Specifications
5
Cabinet and Countertop Layout
WARNING
To reduce the risk of personal injury caused by •
reaching over a hot appliance, avoid locating cabinet
storage space directly above the cooktop.
Failure to meet or exceed the maximum and mini-•
mum dimensions/clearances stated in these instruc-
tions may result in a fire hazard.
Follow the countertop manufacturer’s instructions •
regarding the minimum corner radius, use of heat
reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be •
installed. For best performance, the cooktop should be
placed away from drafts that may be caused by doors,
windows and heating and air conditioning outlets.
This appliance is to be used in conjunction with a suit-•
able vent hood or approved Dacor raised vent system.
Model A: Minimum A: Recommended
SGM304 30” (762 mm) 36” (914 mm)
SGM365 36” (914 mm) 42” (1067 mm)
SGM466 48” (1219 mm) 54” (1372 mm)
Installation Specifications
Allow a minimum ¼” (6 mm) clearance between the •
bottom of the cooktop chassis and all combustible sur-
faces, including the upper edge of a drawer installed
below the cooktop.
Model B: Minimum*
SGM304 29” (737 mm)
SGM365 35 ¼” (895 mm
SGM466 46” (1168 mm)
* To allow clearance for hold down brackets
The gas supply piping, gas shut-off valve and the elec-•
trical outlet must be located so they do not interfere
with the cooktop when it is installed. If installing another
appliance in the cabinet below, allow for the routing of
gas and electrical service behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator when •
the unit is installed.
Access to the electrical outlet when the cooktop is in •
place. The 40” (1016 mm) power cord must be able to
reach the electrical outlet.
Access to the underside of the cooktop for service and •
inspection purposes.
Clearance inside the cabinet to allow for proper hold •
down bracket installation.
To allow access to the utilities and cooktop bottom, a fixed
shelf should not be installed below the cooktop. See the fol-
lowing pages for countertop cutout dimensions.
Raised Vent Compatibility
If installing the cooktop with a raised vent, install only the
approved Dacor model numbers specified below:
Cooktop Models Approved Raised Vent Models
SGM304 ERV30, PRV30 or RV30
SGM365 ERV36, PRV36 or RV36
SGM466 PRV46 or RV46
1/4” (6 mm)
Mimimum clearance
to combustible
surfaces
B
Under Cabinet Clearances
13" Max.**
(330 mm)
** Not applicable for cabinets more than a horizontal distance of
6” (152mm) from edge of cooktop (allow 7 1/2” from edge of cutout).
A
See Cutout
Dimensions
19 5/8" Min.**
(498 mm)
1 7/8" Min.
(48 mm)
Combustible
surface to rear
Combustible overhead
cabinets
31 5/8" Min.*
(803 mm)
7 1/2” (191 mm) Min. to
combustible side wall,
above counter both sides
* If installing with an overhead vent hood, also check hood specific-
ations for minimum required clearances.
All tolerances +1/16” (+1.6 mm), -0
unless otherwise noted.
Minimum Required Clearances Around the Cooktop