Specifications
8
Insert two provided machine screws into the two 3. 
holes above the mounting bracket on the blower 
assembly and tighten into place.
Insert two machine screws through the front of the 4. 
mounting bracket and tighten into place.
Insert two machine screws through the side of both 5. 
āLā brackets and tighten into place.
Attach the end of the duct system to the exhaust out-6. 
let with duct tape.
Hanging the Blower Assembly
 WARNING
Do not use screws to attach the duct work to the hood 
exhaust outlet. Use duct tape only. Screws may prevent 
the damper flaps on the top of the hood from opening.
Inside the exhaust outlet on the top of the blower 1. 
assembly, there are metal or plastic damper flaps. 
The flaps close to help prevent back-drafts when the 
blower is turned off. Remove the shipping tape and 
make sure the flaps open and close freely before pro-
ceeding.
Lift the blower assembly up and put the mounting 2. 
hole on the top over the mounting bracket, while 
inserting the exhaust outlet into the end of the duct 
system. Gently lower the blower assembly onto the 
lip of the mounting bracket. Slide the bottom part of 
the blower assembly between the two āLā brackets.
Installation Instructions
Blower 
assembly
Exhaust 
outlet
Insert exhaust 
outlet into end 
of duct
Mounting 
bracket
"L" brackets