Installation guide
Installation 
Specifications 
WARNING 
« 
~ 
Observe 
all- 
governing  codes 
and 
ordinances. 
during 
planning-and 
installation. 
Contact-your 
local 
building 
department 
for 
further 
information. 
«. 
The 
minimum 
installed 
distance 
from 
the 
rear.of 
blower.-unit 
base 
to 
the 
cooktop 
surface 
must 
be 
no.less 
than 
30” 
inches 
(76.2 
cm), 
26 
inches 
(66.0 
cm) 
for-an 
electric 
cooktop. 
The 
minimum 
specified 
distance 
may 
be 
higher. 
for 
the 
particular-range 
or 
cooktop 
in-use. 
Check 
the 
manufacturers 
specifica- 
tions 
for-the 
cooktop 
or 
range. 
Product 
Dimensions 
Tolerances: 
1/16” 
(£1.6 
mm), 
-O 
unless 
otherwise 
stated 
10 
3/4" 
(27.3em) 
11 
7/8" 
(30.2 
cm) 
ond 
—— 
— 
8" 
dia. 
eee 
203.2 
cm) 
26 
1/8" 
(66.4 
cm) 
__ 
Aa 
min.* 
[ee 
44" 
(111.8 
cm) 
max" 
95 
3/8"* 
193/4"* 
(64.5 
cm) 
(90.2 
em) 
5 
3/4" 
= 
(14.6 
cm) 
19 
3/4” 
(50.2 
cm) 
30” 
(76.2 
cm) 
or 
36” 
(91.4 
om)* 
* 
Glass 
thickness 
of 
5/16” 
(3 
mm) 
not 
included 
™ 
Glass 
width 
must 
be 
specified 
at 
time 
of 
order. 
Specify 
glass 
part 
number: 
PHGXXBK 
where 
XxX 
is 
the 
width. 
Planning 
the 
Location 
NOTE: 
The 
mounting 
hardware 
includ- 
ed 
with 
the 
hardware 
packet 
is 
suitable 
Carefully 
check 
the 
location 
where 
the 
hood 
is 
to 
be 
installed. 
The 
hood 
should 
be 
placed 
for 
convenient 
access. 
Make 
certain 
that 
electrical 
power 
can 
be 
provided 
in 
the 
selected 
location. 
Plan 
the 
installation 
so 
that 
all 
minimum 
dimensions 
shown 
are 
met 
or 
exceeded. 
Dimensions 
shown 
pro- 
vide 
minimum 
clearances, 
unless 
otherwise 
noted. 
All 
contact 
surfaces 
between 
the 
hood 
and 
any 
cabi- 
nets 
or 
walls 
must 
be 
solid 
and 
at 
right 
angles. 
install 
the 
range 
hood 
and 
cooking 
appliance(s) 
so 
that 
they 
can 
be 
removed 
if 
service 
is 
required. 
Rear 
of 
blower 
unit 
5/16” 
(3mm) 
| 
Glass 
A 
J 
30" 
rin 
Cooktop 
(76.2 
em) 
surface 
CO 
Side 
View 
for 
mounting 
to 
brick 
and 
masonry 
. 
of 
. 
*, 
Operati 
ae 
Specifications 
only. 
If 
mounting 
the 
range 
hood 
to 
dry- 
: 
wall, 
Dacor 
strongly 
recommends 
the 
i 
Blower 
600 
CFM 
max. 
using 
an 
anchoring 
system 
designed 
Blower 
Speeds 
4 
with 
electronic 
speed 
control 
| 
for 
use 
with 
drywall. 
In 
addition, 
Dacor 
; 
trongly 
recommends 
that 
you 
install 
a 
: 
Light 
120 
Vac, 
50 
Watt, 
hal 
1 
S 
9 
= 
a 
att, 
halogen 
(1) 
reinforced 
mounting 
block 
between 
the 
Filters 
Mesh 
type, 
dishwasher 
safe 
(2) 
|  studs 
behind 
all 
hood 
mounting 
loca- 
Exhaust 
8 
inch 
tions. 
: 
Finish 
430 
stainiess 
steel 
: 
with 
tempered 
glass 
hood 
: 
Total 
Connected 
Load 
|  120 
Vac, 
60  Hz. 
3.5 
Amp. 
: 
Circuit 
120 
Vac, 
15 
Amp. 
grounded, 
Requirement 
dedicated 
circuit, 
min. 
dacor 
3