Installation Instructions Renaissance ® Downdraft Vent Models ERV3015, ERV36-ER, ERV3615, ERV48, ERV48-ER, PRV30, PRV36 and PRV46 Includes installation instructions for cabinet blower (Dacor model CABP3) which is an option for models ERV3015 and ERV3615. Use these downdraft vents only with approved Dacor ® appliances. See the installation instructions for the particular appliance model being installed to determine suitability. Part No. 107736 Rev.
Table of Contents Important Safety Instructions........................................... 1 Important Information About Safety Instructions............... 1 Safety Symbols and Labels.............................................. 1 General Safety Precautions.............................................. 2 Product Specifications...................................................... 2 Electrical Specifications.................................................... 2 Product Dimensions - ERV3015 and ERV3615......
Important Safety Instructions Important Information About Safety Instructions • • The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you don’t understand. See Customer Service Information.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety precautions, including the following: Warning warning • Do not install or operate a damaged appliance. If you receive a damaged appliance, contact your dealer or builder. • The installer must show the customer the location of the electrical outlet so that the customer knows where and how to disconnect power.
Product Specifications Product Dimensions - ERV3015 and ERV3615 Tolerances: ±1/16” (±1.6 mm) unless otherwise stated 2 3/16” (5.6 cm) 2 1/8” 5/16” (8 mm) thick stiffener (5.4 cm) across back Top cap with vent down 3/16” (5 mm) 3” (7.6 cm) Model Number A - Top Cap Width B - Chassis Width ERV3015 30” (76.2 cm) 27 3/8” (69.5 cm) ERV3615 36” (91.4 cm) 33 3/8” (84.8 cm) 9/16” (1.4 cm) 2 1/8" (5.4 cm) ERV top cap - side view 1 15/16” (4.9 cm) 2 9/16” * (6.
Product Specifications Product Dimensions - ERV48 and PRV Series Tolerances: ±1/16” (±1.6 mm) unless otherwise stated 2 3/16" (5.6 cm) 5/16” (8 mm) thick stiffener across back 2 1/8" (5.4 cm) Top cap with vent down 3/16" (5 mm) 2 1/2" (6.4 cm) 9/16" (1.4 cm) Model Number A - Top Cap Width B - Chassis Width ERV48 48” (121.9 cm) 43 3/8” (110.2 cm) PRV30 30” (76.2 cm) 27 3/8” (69.5 cm) PRV36 36” (91.4 cm) 33 3/8” (84.8 cm) PRV46 46” (116.8 cm) 43 3/8” (110.2 cm) 1 15/16" (4.
Product Specifications Product Dimensions - ERV36-ER and ERV48-ER 5/16” (8 mm) thick stiffener across back 1/4" (6 mm) 2 13/16" (7.1 cm) 2 1/2" (6.4 cm) Top cap with vent down Model Number Top Cap Width (A) Chassis Width (B) ERV36-ER 36” (91.4 cm) 33 3/8” (84.8 cm) ERV48-ER 48” (121.9 cm) 43 3/8” (110.2 cm) Tolerances: ±1/16”, (±1.6 mm) unless otherwise stated 1 15/16" (4.9 cm) 2 9/16" (6.5 cm) A Vent shown in raised position 10" (25.4 cm) B 18 5/8” (47.3 cm) 3 3/4" (9.5 cm) 1" (2.
Installation Specifications Planning the Installation General System Layout Backsplash The vent system consists of the downdraft vent itself and a single Dacor approved cabinet blower (models ERV3015 and ERV3615), remote blower or in-line blower (see facing page for examples). Countertop overhang warning • Failure to install an approved blower or proper duct work will result in a back draft and/or the insufficient venting of smoke and fumes.
Installation Specifications Backsplash Front of unit Cooktop Cabinet blower option on ERV3015, and ERV3615 only Connection to cabinet blower Connection to remote/in-line blower Downdraft vent Blower wiring access hole Cabinet blower, option on ERV3015 and ERV3615 only Wall Floor Blower wiring access hole Wall cap 3 1/4 x 10 90° elbow Electrical Layout 12” min. (30.
Installation Specifications Planning the Duct Work Installations with ILHSF and REMP series blowers: warning • To reduce the risk of fire and to properly exhaust air, be sure to duct air outside the house or building. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages. • TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. • DO NOT install more than one blower to increase the length of the duct run.
Installation Specifications 6 1/4" Front of unit Motor cover 26" (66.0 cm) 1 1/8" (2.9 cm) CL (15.
Installation Specifications Exhaust Locations and Dimensions for CABP3 Cabinet Blower Installations (ERV3015, ERV3615 only) ERV Cooktop Model A B C ERV3015 12 1/8” (30.7 cm) 5 5/8” (14.4 cm) 1 3/4” (4.4 cm) ERV3615 9 3/4” (24.8 cm) 8” (20.3 cm) 4 1/4” (10.8 cm) CABP3 C L Countertop ADAPTER 8 7/8" (22.5 cm) from back of ERV cutout to center line of CABP3 exhaust in any orientation A 26 1/4” (66.
Installation Specifications Calculating the Maximum Duct Run Length Duct Work Design Tips • For optimal performance, consult a qualified HVAC specialist when designing the duct system. • • Do not use duct work that is smaller in cross-sectional area than the required duct sizes in the tables below. • Keep the duct run as short as possible for best performance and never exceed the maximums stated in the table below right.
Installation Instructions Installation Preparation Verify Package Contents 1. Unpack the unit and verify that all required parts have been provided. If any item is missing or damaged, please contact your dealer immediately. Do not install a damaged or incomplete appliance. The customer must report cosmetic issues within 30 days of installation.
Installation Instructions Adapter Installation for CABP3 Blower: (optional, ERV3015 and ERV3615 only) 1. Remove the front cover so that the AERVCAB cabinet blower adapter can be installed. To do so, remove and retain the three (3) wing nuts and three (3) flat washers on the front of the unit. Discard the three (3) lock washers (they will be replaced). Tilt the cover out and pull up. to remove it. Installing the Downdraft Vent in the Cutout 1.
Installation Instructions Cabinet Blower Installation: ILHSF or REMP Series Blower Installation (optional, ERV3015 and ERV3615 only) If using a ILHSF or REMP series blower, install it according to the blower installation instructions. 1. Locate the wiring diagram label included with the adapter kit. Peel the protective backing off and place it over the existing label on the CABP3 blower as shown.
Installation Instructions Wires to power plug. Pre-wired at factory. Do not modify. Match wire colors to terminals as shown. Front of unit BLACK WHITE Electrical connection from downdraft vent, match Wire Colors Electrical access panel Ground Power Input Blower Output CABP3 cabinet blower GREEN Attach ground wire as shown Downdraft vent blower wiring access hole Electrical Installation - CABP3 Cabinet Blower Blower power wiring/conduit. Connect other end of wires to blower terminal block.
Installation Instructions Verifying Proper Operation warning • Read the downdraft vent use and care manual completely before operation. • Install all of the front filters prior to operating the downdraft vent. Refer to the use and care manual for filter installation instructions. caution To prevent damage to the downdraft vent power cord, route it away from the surfaces of the range or cooktop before connecting it. 1. Make sure the power switch on the top of the downdraft vent is in the up position. 2.
Technical Data Wiring Diagram - All Models UP LIMIT SWITCH DOWN LIMIT SWITCH SNORKEL SWITCH COM COM COM NO NC NC NO RED RED BLUE BLK YEL NO NC CHASSIS GROUND STUD WHT WHT YEL WHT BLUE REMOTE POT RELAY N SPEED CONTROL BLK ORNG L ORNG COM NO L2 N2 BLOWER OUTPUT RED L1 N1 GND GND POWER INPUT GROUND BLK CABP3 Cabinet Blower Ratings CABP3 Blower Performance Nominal 600 CFM Actual 585.6 CFM * At zero inches static pressure.
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.