Planning Guide

PLANNING
GUIDE
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
Cabinet Layout
For safe operation, maintain all specified maximum/minimum
dimensions and clearances.
Install the range away from drafts (open doors/windows, home
ventilation).
Do not install cabinets directly above the range, or reduce risk
of fire and injury (from reaching over an active cooktop) by
installing a range hood that projects horizontally at least 5”
beyond the cabinet bottom.
You may place the range against the rear wall. Dacor recommends
installing non-combustible material on the wall between the
range and vent hood. Non-combustible material directly behind
the range is not needed, but seal any openings in the wall behind
the range and in the floor beneath it.
Gas and Electrical Service
Locate the gas inlet and electrical outlet in an adjacent cabinet
(see the cabinet graphic). If replacing the range, existing utilities
may be used if they do not impede the new range’s placement.
Check building codes for permissible gas-valve locations.
An external, manual shut-off valve must be installed between
the gas inlet and range so gas to the range can be turned on/off.
Location of the gas-supply piping and shut-off valve, and the
electrical outlet must not interfere with placement of the range.
The gas valve and electrical outlet must be accessible without
moving the range.
Install the gas shut-off valve so the range can be pulled out for
service/cleaning without disconnecting the conduit.
Heritage
®
36”, 48” Wide
Gas Pro Range
Page 3 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
HGPR36S, HGPR48S
CUTOUT DIMENSIONS
Model
F—recommended/
min
G—min/
max
H
HGPR36
42” (106.7 cm)/
36” (91.4 cm)
36” (91.4 cm)/
36 ” (91.8 cm)
33 ” (84.8 cm)
HGPR48
54” (137.2 cm)/
48” (122.0 cm)
48” (121.9 cm)/
48 ” (122.2 cm)
43 ” (110.5 cm)
Callout Description
1
Grate top to combustible overhead surface. NOTE: If installing a vent
hood, check hood specifications for minimum required clearances.
2
Cabinet face must NOT extend beyond rear of front panel (see
Product Dimensions, Pg. 1).
3
Consult local code for exact location requirements.
4
Vertical from top of grate to combustible surface.
5
Does not apply for cabinets more than a horizontal distance of 10”
(25.4 cm) from edge of range.