planning guide

PLANNING
GUIDE
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
Heritage
®
30” Wide
Epicure Gas Range
Page 3 of 3
All tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
HGER30S
Cabinet Layout
For safe operation, maintain all specified maximum and
minimum dimensions and clearances.
Install the range away from drafts (open doors/windows, home
ventilation).
Do not install cabinets directly above the range, or reduce risk
of fire and injury (from reaching over an active cooktop) by
installing a range hood that projects horizontally at least 5”
beyond the cabinet bottoms.
You may place the range against the rear wall. Dacor recommends
installing non-combustible material on the wall between the
range and vent hood. Non-combustible material directly behind
the range is not needed, but seal any openings in the wall behind
the range and in the floor beneath it.
Callout Description
1
Vertical from top of grate to combustible overhead surface.
NOTE: If installing a vent hood, check hood specifications for
minimum required clearances.
2
Cabinet face must NOT extend beyond rear of front panel (see
Product Dimensions, Pg. 1).
3 Consult local code for exact location requirements.
4 Vertical from top of grate to combustible surface.
5
Does not apply for cabinets more than a horizontal distance of
10” (25.4 cm) from edge of range.
F G H
36”* (91.4 cm); 30”** (76.2 cm) 30”** (76.2 cm) 27 ” (69.9 cm)
*recommended; **minimum
Gas and Electrical Service
The small grey box in the cabinet graphic below is the
recommended location of the gas inlet and electrical outlet. If
replacing the range, existing utilities may be used if they do not
interfere with the new range’s placement. Check building codes
for permissible gas-valve locations.
An external, manual shut-off valve must be installed between
the gas inlet and range so gas to the range can be turned on/off.
Location of the gas-supply piping and shut-off valve, and the
electrical outlet must not interfere with placement of the range.
The gas valve and electrical outlet must be accessible without
moving the range.
Locate the gas shut-off valve so the range can be pulled out for
service/cleaning without disconnecting the conduit.