Planning Guide
Table Of Contents
• Seal openings in the wall behind the range and in the floor below.
• The g
rey area in the diagram below shows the suggested gas/
electrical utilities. Existing utilities may be used if they do not
hinder range placement.
• Gas/electrical u
tilities must be located so the range can be
moved for service without beingdisconnected.
• An ex
ternal, manual shut-off valve must be installed between
the gas inlet and range so gas to the range can be shut on/off.
• Installation m
ust allow access to the gas shut-off valve and
circuit-breaker panel/fuse box when the range is in place.
Cabinet Layout
• All ma
ximum/minimum dimensions and clearances in the
diagrams below must be maintained for safeoperation.
• Place t
he range away from drafts (open doors and windows,and
h
ome heating/cooling systems).
• Do not i
nstall cabinets over the range, or to reduce risk of burn
i
njury from reaching over a hot cooktop, install a range hood tha
t
p
rojects horizontally at least 5” beyond the cabinet bottoms.
• The r
ange may be installed against the rear wall. Dacor strongly
recommends installing a backguard or non-combustible
material on the rear wall between the range vent hood.
Heritage
®
30”, 36”, 48” Wide,
Dual-Fuel Ranges
PLANNING
GUIDE
Page 3 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
HDPRS/H DERS
Standard Cutoutwith
Range Hood
APPROVED DOWNDRAFTVENTS
Range Downdraft Vent
HDPRS/HDERS 30 N/A
HDPRS/HDERS 36 MRV36-ER
HDPRS/HDERS 48 MRV48-ER
IMPORTANT: See downdraft installation instruc-
tions for duct and electrical installation require-
ments. Use only approved Dacordowndraft vents.
CUTOUT DIMENSIONS
Model F: recommended/min. G: min./max. H
HDPRS/HDERS 30 36” (91.4 cm) / 30” (76.2 cm) 30” (76.2 cm) / 30 1/8” (76.5cm) 27 3/8" (69.5 cm)
HDPRS/HDERS 36 42” (106.7 cm) / 36” (91.4cm) 36” (91.4 cm) / 36 1/8” (91.8 cm) 33 1/2” (84.8 cm)
HDPRS/HDERS 48 54” (137.2 cm) / 48” (122.0 cm) 48” (121.9 cm) / 48 1/8” (122.2 cm) 43 1/2” (110.5 cm)
Countertop Cutout For Downdraft Vent
1. Vertical from range grate level to combustible overhead surface; if install-
ing an overhead hood, see hood specifications for minimum required
clearances.
2. Cabinet/countertop depth is a
t customer discretion, but cabinet face must
not protrude beyond rear of range front panel. (See Pg. 1for dimensions.)
3. Consult lo
calcodes for exact location requirements.
4. Vertical f
rom grate level to combustible surface.
5. Not a
pplicable to cabinets that horizontally are over10” (25.4 cm) from
range edge.
All specifications subject to change without notice. www.dacor.com Ph. 800.793.0093