Specifications

5
Installing the ERV/PRV
NOTE:
The vent must be installed in a
vertical orientation. Do not mount
the vent on a slant or angle.
Remove the knockout from the plenum by
cutting the tape and metal cross overs to
remove the insert.
Loosely attach the anchoring legs to the left
and right sides of the plenum using the hex
nuts provided. Place the vent into the rear of
the countertop cutout. Adjust the anchoring leg
height so that the end caps are gently resting on
the counter, then tighten the hex nuts. Secure
the anchoring legs to the cabinet/floor with the
screws provided.
Connecting the Exhaust Duct
NOTE:
Use duct tape to seal the
connection between the blower
outlet and duct. Support the duct
weight as necessary to ensure
sealed joints.
For the side or bottom knockouts use the
supplied transition (ATD2-P/N 13768). For the
rear knockout attach a 3 1/4" x 10" duct.
For installation of the raised vent system,
provide an opening in the countertop as shown
in the Countertop Preparation Section. Position
the cutout so all required minimum clearances
are met. Make certain that the minimum flat
countertop area meets or exceeds the combined
overall width and overall depth, as shown.
Electrical Connection
WARNINGS:
1. Ensure that the power supply
is disconnected before
proceeding.
2. Verify that the power supply
matches the ratings found on
the appliance data plate before
proceeding.
3. The complete appliance must
be properly grounded at all
times when electrical power is
applied.
4. Do not ground the appliance
with the neutral (white) house
supply wire. A separate
ground wire must be utilized.
5. If aluminum house supply
wiring is used, splice the
appliance copper wires to the
aluminum house wiring with
special connectors designed
and agency-certified for this
purpose. Follow the connector
manufacturers recommended
procedure carefully. Improper
connection can result in a fire
hazard.
6. Failure to complete electrical
connections properly may
result in a damaged or non-
functional system. Follow the
wiring diagrams carefully to
ensure a proper installation.
Both vent systems require a properly grounded,
120 VAC, 60 Hz., 15 Amp electrical service.
Max. full line load is 8 amps. Always use a
dedicated circuit. Do not use the same circuit
that the cooktop is using.
NOTE:
The power cord is to be routed
beneath the appliance and routed
away from heat generated by the
cooktop.
NOTE:
Verify that the raised vent and
blower being installed are a
matched pair before beginning the
installation.
22 7/16"
(570mm)
23 1/4"
(591mm)
Min.
7 1/2" (191mm) Min.
to combustible side
walls above the range
(both sides)
25"
(635mm)
Backsplash
Max.3/4" (19mm)
1/4" (6mm)
Min. flat ledge
Vertical
non-combustible
surface rear wall
Flush with
backside of
cabinet front
A
19 7/8"
(505mm)
23 1/4"
(591mm)
Min.
7 1/2" (191mm) Min.
to combustible side
walls above the range
(both sides)
25"
(635mm)
Backsplash
Max.3/4" (19mm)
1/4" (6mm)
Min. flat ledge
Vertical
non-combustible
surface rear wall
Flush with
backside of
cabinet front
2 9/16"
(65mm)
B
A
Overall Cutout Dimensions
(SGM364, SGM365)
Overall Cutout Dimensions
(CER304, CER365, ETT304, ETT365, SGM304, SGM466, SGM464GG)
Dacor
Model No.
Cutout
“A”
Cutout
“B”
CER304 28 1/2” 27 1/2”
CER365 34 1/2” 33 1/2”
ETT304 28 1/2” 27 1/2”
ETT365 34 1/2” 33 1/2”
SGM304 27 1/2” 27 7/8”
SGM364 33 3/4” 33 3/4”
SGM365 33 3/4” 33 3/4”
SGM466 44 1/2” 43 1/2”
SGM464GG 44 1/2” 43 1/2”