Installation Requirements
In Preparation
1. Before cutting the opening in the countertop, verify that there will be no conflict between the
rangetop chassis and anything in the cabinet below.
2. Remove all packing material and accessories from the rangetop, and verify that all items are
present before beginning the installation.
Before you begin the nstallation, review this section thoroughly. These dimensions must be met for
safe operation. Location of the electrical outlet and gas piping may be adjusted to meet the specified
parameters.
CAUTION
The rangetop complies with the maximum allowable wood-cabinet temperature of 194 °F (90 °C).
Ensure the wall covering, countertops, and surrounding cabinets can withstand this temperature to
avoid discoloration, delamination, or melting.
Maintain These
Minimum Clearances
Rangetop DTT36M974 DTT48M976
A 36" (91.41 cm) 48" (121.9 cm)
B
36" (91.41 cm)*
42" (106.7 cm)**
48" (121.9 cm)*
54" (137.2 cm)**
* Minimum
** Recommended
A: Rangetop cutout
B: Range hood cutout
Location Requirements
1
Vertical to combustible surface from
rangetop grate level; if installing a
ventilation hood, check hood spec's for
minimum required clearances.
2
See Cabinet/Countertop Dimensions
Top View.
3
This specification is not applicable for
cabinets more than a horizontal
distance of 10" (25.4 cm) from the edge
of the rangetop.