Installation Instructions Modernist Rangetop DTT48M976/DTT36M974 Part No.
Contents Before You Begin 3 Important Notes 3 Customer-Assurance Information 4 Important Safety Instructions 5 Product Specifications 9 What Is In the Box Parts and Tools Needed 9 10 Installation Requirements 11 In Preparation Overall Rangetop Dimensions Countertop Cutout Dimensions Gas-Supply Requirements Special Gas Requirements (gas models sold In Massachusetts) Electrical Requirements 11 12 13 17 17 18 Installation Instructions 19 Installing the Rangetop 19 2 English
Before You Begin Important Notes User • Keep this manual for personal and professional reference. • Ensure that qualified personnel install and ground the rangetop. Overall design/accessories may differ with the model. Installer • Read this manual thoroughly before installation. • Leave this manual with the user. • Write the rangetop's modal/serial numbers in this manual for service/maintanance reference. • Remove all packaging from the rangetop before connecting it to the electric/gas supplies.
Customer-Assurance Information To resolve questions and installation issues, contact your Dacor dealer or the Dacor Customer Assurance Team. Before calling, have the rangetop's model/serial numbers available (see the data label, right-hand side of the rangetop chassis.) Label Dacor Customer Assurance Phone: (800) 793-0093 x2813 (USA, Canada) Hours of Operation: Mon – Fri 5:00 a.m. to 5:00 p.m. Pacific Time Website: www.dacor.
Important Safety Instructions Read All Instructions Before Using This Appliance • All electrical/gas equipment with moving parts can be dangerous. Read and follow this section carefully to minimize risk of property damage, personal injury, and death. • Keep this manual in a handy place for personal and professional reference. Symbols Used In This Manual Follow these warning icons and symbols explicitly to prevent property damage and personal injury.
Important Safety Instructions General Safety, cont. • Do not use the rangetop as a space heater. • Air curtains or range hoods that blow air downward shall not be used with a gas range unless the hood and range are designed and tested according to the Standard for Domestic Gas Ranges, ANSI Z21.1 • CSA1.1, and listed by an independent testing laboratory for combination use.
Important Safety Instructions Electrical and Grounding Safety WARNING To reduce risk of fire, electric shock, personal injury, and death: • Plug the appliance in to a grounded, 3-prong outlet. • Do not remove the ground prong. • Do not use an adapter or an extension cord. • Do not use a damaged power plug/cord, or loose power outlet. • Do not modify the power plug, cord, or outlet. • Do not put a fuse in a neutral or ground circuit. • Use a dedicated 120-volt, 60-Hz, 20-amp, AC, fused electrical circuit.
Important Safety Instructions Rangetop Safety WARNING To reduce risk of fire, electric shock, personal injury, and death: • Turn all burners are off when not in use. • Do not use aluminium foil to line the grates or any part of the rangetop. • Do not leave burners unattended on medium or high heat settings. • Before igniting, ensure all burner caps are properly in place and all burners are level. • Always use the LITE position to ignite the burners, then ensure the burners ignite.
Product Specifications What Is In the Box Common Parts Manual Regulator (1) * Bolt (2) Washer (2) Envelope (1) 36" DTT36M974 Cooktop burner grates (2) Burner heads (4) and Brass caps (5) Porcelain caps (4) Burner heads (6) and Brass caps (7) Porcelain caps (6) 48" : DTT48M976 Cooktop burner grates (3) NOTE • • • Verify that all supplied parts are present. If your rangetop was damaged during shipping or specified parts are missing, contact your local retailer.
Product Specifications Parts and Tools Needed Parts Needed Gas line shut-off valve Flexible metal appliance connector ½ in (ID) x 5 ft 135-degree elbow (option) 90-degree elbow (option) Flare union adapter ¾ in (NPT) x ½ in (ID) Flare union adapter ½ in (NPT) x ½ in (ID) Tools Needed Flat-blade screwdriver Phillips screwdriver Open-end or adjustable wrench Pipe wrench (2) ¼" Nut driver Pencil, ruler Level Pipe-joint compound Utility knife Soap-water solution Pliers Saber saw 10 English
Installation Requirements In Preparation 1. Before cutting the opening in the countertop, verify that there will be no conflict between the rangetop chassis and anything in the cabinet below. 2. Remove all packing material and accessories from the rangetop, and verify that all items are present before beginning the installation. Location Requirements Before you begin the nstallation, review this section thoroughly. These dimensions must be met for safe operation.
Installation Requirements Overall Rangetop Dimensions DTT36M974 28 3/16" (71.6 cm) 27 1/2" (69.9 cm) 25 11/16" (65.3 cm) 22 1/4" (56.5 cm) 36" (91.1 cm) DTT48M976 48" (121.6 cm) 28 3/16" (71.6 cm) 27 1/2" (69.9 cm) 25 11/16" (65.3 cm) 22 1/4" (56.
Installation Requirements Countertop Cutout Dimensions Cabinet/Countertop Dimensions (front view) 10” (25.4 cm) to combustible side wall min. both sides 1 1/2” (3.8 cm) typical countertop thickness 1/2” (1.3 cm) overhang, both sides 7 3/4” (19.7 cm) A Recommended gas and electrical service location, consult local code Mounting platform 1” (2.5 cm) min. thickness 36” (91.4 cm) typical Installed Rangetop (side view) 24” (61.0 cm) Installed control panel overhang 1 3/8” (3.
Installation Requirements Countertop Cutout Dimensions, cont. Installed Rangetop (side view) Gas and electrical connections at right rear section of chassis 24” (61.0 cm) Installed control panel overhang 1 3/8” (3.5 cm) Countertop Cabinet face Mounting platform Gas connection and power cord may be routed through bottom or back of chassis Cabinet/Countertop Cutout Dimensions—No Downdraft Vent (top view) Rangetop Model A B C DTT36M976 36” (91.4 cm) 35” (88.9 cm) 16 5/8” (42.
Installation Requirements Countertop Cutout Dimensions, cont. Cabinet/Countertop Cutout Dimensions—With Downdraft Vent (top view) NOTE Gas and electrical connections must be routed through the bottom of the rangetop when installed with a downdraft vent. Model A: Cutout Width B: Hole Offset C: Downdraft Vent Cutout Approved Downdraft Vent Models* DTT36M976 36” (91.4 cm) 16 5/8” (42.2 cm) 33 1/2” (85.1 cm) MRV3615M/S DTT48M976 48” (121.9 cm) 20 13/16” (52.9 cm) 43 1/2” (110.
Installation Requirements Countertop Cutout Dimensions, cont. Cabinet/Countertop—With Downdraft Vent (side view) 3/8” min. (1.0 cm) flat countertop overhang required behind cutout Countertop DTT36M974 or DTT48M976 rangetop Stiffener 3/8” min. (1.0 cm) space behind downdraft vent chassis to clear stiffener Minimum countertop height: 30 1/4" (76.
Installation Requirements Gas-Supply Requirements Provide Adequate Gas Supply The rangetop operates at a manifold pressure of: • • 5 in. (13 cm) of water column for natural gas/natural-gas-at-high-altitude (NG-H) or 10 in. (25 cm) of water column for LP gas (propane)/LP-gas-at-high-altitude (LP/H). Ensure your rangetop receives the proper gas. When verifying regulator function, the inlet pressure must be at least 1 in. (2.5 cm) greater than the given operating (manifold) pressure.
Installation Requirements Electrical Requirements WARNING The owner shall verify that the electrical service meets electrical requirements and that the outlet is properly installed by a licensed electrician. • To reduce risk of fire, electric shock, or personal injury: - Do not use an extension cord or adapter plug with the rangetop. - The rangetop must be properly grounded. - Do not use a damaged power plug or loose wall outlet.
Installation Instructions Installing the Rangetop IMPORTANT Carefully read these instructions and the Important Safety Instructions (Pg. 5) before installing/ operating the rangetop. Improper installation, adjustment, service, or maintenance can lead to personal injury and property damage. Product failure due to improper installation is not warrantied. NOTE Only qualified personnel should install the rangetop. Unpacking the Rangetop 1. Remove all packaging. (Failure to do so could damage the rangetop.) 2.
Installation Instructions Installing the Rangetop, cont. Connecting the Gas Supply, cont. Never install an old connector on a new appliance. For hard piping, carefully align the pipe; the rangetop cannot be moved after the connection is made. To prevent gas leaks, apply pipe-joint compound or wrap pipe-thread tape with Teflon on all male (external) pipe threads. 1. Attach the provided gas-pressure regulator to the rangetop pipe nipple inlet.
Installation Instructions Installing the Rangetop, cont. Making the Electrical Connections WARNING • • • Disconnect power at the main circuit breaker or fuse box before making electrical connections. BEFORE operating/testing, follow the grounding requirements (pg. 30) of this manual. Improper connection of the grounding plug is an electric-shock risk. The electrical system (including power cord) is factory-installed/-wired. Altering any part of this system may cause a short or overload. 1.
Installation Instructions Installing the Rangetop, cont. Dual Burner Heads/Caps 1. Orient the burner head so the opening for the electrode aligns with the electrode. 2. Install the burner head so the electrode passes through its opening in the head. Ensure the burner head lies flat on the stove top. 3. Size the burner caps to the burners, then install the caps on the heads. Round Burner Head/Caps 1. Put the burner heads on the burner bases. The bottom of the head fits within the burner base. 2.
Installation Instructions Installing the Rangetop, cont. SimmerSear Burner Assembly 1. Place the burner heads as shown. The locater tab on the head goes in the keyed hole as shown. Burner head Locating tab Keyed hole Burner base Burner ring 2. Put the burner rings on the heads as shown. Match the tabs on the bottom of the ring to the slots on the head. Wiggle each ring to ensure it is properly seated. Ridge on bottom of burner cap 3. Put the burner caps on the burner rings.
Installation Instructions Installing the Rangetop, cont. Checking Flame Quality All burner flames must be visually checked to assess their quality. CAUTION If you want measure the flame, take care to avoid burn injuries. 1 2 3 1. Soft blue flames—Normal for natural gas. 2. Yellow tips on outer cones—Normal for LP gas. 3. Yellow flames—Abnormal for any gas operation. NOTE If the burner flame looks like Ex. 3, call for service, and do not use the rangetop. Ex. 1 or 2 are normal burner flames.
Installation Instructions Installing the Rangetop, cont. Final Installation Checklist After installing the rangetop, ensure all control knobs are OFF. Review this checklist to confirm the rangetop is properly installed and ready to operate. • The gas line was properly connected to the rangetop. • The gas was turned on. • All connections were checked for leaks. • The rangetop is properly plugged in to a grounded electrical outlet. • The rangetop burners and grates are properly assembled.
Notes 26 English
Notes English 27
DG68-00942A-00 Dacor ∙ 14425 Clark Avenue, City of Industry, CA 91745 ∙ Phone: (800) 793-0093 ∙ Fax: (626) 403-3130 ∙ www.dacor.