Installation Manual
English48 
Installation instructions
Installation instructions
Installing a 4-wire conduit
•  Aluminum building wire may be used but it must be rated for the correct amperage 
and voltage. Connect wires according to this Step 4 depending on the number of wires.
•  Wire used, location and enclosure of splices, etc., must conform to good wiring 
practices and local codes.
Ground strap
Ground plate
White
Black
Red
Neutral 
terminal
Ground wire 
(Green)
Wire 
tips
White
Black
Red
1.  Loosen the 3 lower terminal screws 
from the terminal block. Remove the 
ground screw and ground plate and 
retain them.
2.  Cut and discard the ground strap. Do 
not discard any screws.
3.  Insert the ground bare wire tip 
between the range frame and the 
ground plate (removed earlier) and 
secure it in place with the ground 
screw (removed earlier).
4.  Insert the bare wire (white/neutral) 
tip through the bottom center of the 
terminal block opening.
5.  Insert the two side bare wire tips into 
the lower left and the lower right 
terminal block openings.
6.  Tighten the screws until the wire is 
firmly secured (35 to 50 inch-lbs.). Do 
not over-tighten the screws since it 
could damage the wires.
Install_NY9900M_PRORANGE_DOP48M96DLM_DA_DG68-00936A-00_EN+MES+CFR.indb 48 2017-05-12  7:36:52