Installation Manual
English  33 
Installation requirements
Electrical requirements
•  Failure to follow these instructions can result in death, fire, or electrical shock.
WARNING
•  It is the owner’s responsibility to make sure that the electrical service meets electrical 
requirements and that he electrical outlet has been properly installed by a licensed 
electrician.
•  To reduce the risk of fire, electric shock, or personal injury:
All range
•  Do not use an extension cord or adapter plug with this range.
•  This range must be properly grounded.
•  Check with a qualified electrician if you are in doubt as to whether your range is 
properly grounded.
•  Do not modify the range power plug. If it does not fit the outlet, have a proper outlet 
installed by a qualified electrician.
•  All wiring and grounding must comply with local codes or, in the absence of local 
codes, with the National Electrical Code, ANSI/NFPA No. 70 – Latest Revision (US), or 
the Canadian Electrical Code CSA C22.1 – Latest Revisions and local codes.
•  Wiring diagram is located on the back of the range. (Inside of the cover back wire)
•  The range’s electronic ignition system will not operate if the outlet is not properly 
polarized.
•  A dedicated circuit breaker is recommended.
•  Use the chart below to determine the minimum recommended dedicated circuit 
protection.
KW Rating (240 V) Recommended Circuit Size (Dedicated)
7.3 KW - 9.6 KW 40 Amp
9.7 KW - 12.0 KW 50 Amp