Installation Manual
English24 
Installation requirements
Installation requirements
Pre-installation checklist
1.  Before preparing the opening in the countertop or cabinet, verify that there will be no 
conflict between the range and anything in the cabinet below.
2.  Remove packing materials, grate boxes, regulator with literature, and literature 
package from the range, verify that all items are present before beginning the 
installation.
General requirements
Clearances and dimensions
•  For OTR over Gas Stove, please follow local GAS CODE.
•  BEFORE YOU BEGIN to install this appliance, refer to the following information, 
dimensions, and clearances. Do not locate the range where it may be subject to strong 
drafts. Provide adequate clearances between the range and adjacent combustible 
surfaces. These dimensions must be met for safe use of the range. The location of the 
electrical outlet and gas piping may be adjusted to meet the following dimensions and 
clearances.
•  The range may be installed flush to the rear wall. Dacor strongly recommends installing 
a non-combustible material on the rear wall above the range and up to the vent hood 
or installation of a backguard. It is not necessary to install non-combustible materials 
behind the range below the countertop height. Any openings in the wall behind the 
appliance or in the floor underneath it must be sealed.
•  For installation in Canada, a free-standing range is not to be installed closer than 4.7 in 
(12 cm) from any adjacent surface.
CAUTION
This range has been designed to comply with the maximum allowable wood cabinet 
temperature of 194 °F (90 °C). Make sure the wall covering, countertops, and cabinets 
around the range can withstand the heat (up to 194 °F [90 °C]) generated by the range. If 
not, discoloration, delamination, or melting may occur.
Install_NY9900M_PRORANGE_DOP48M96DLM_DA_DG68-00936A-00_EN+MES+CFR.indb 24 2017-05-12  7:36:47