Installation Instructions
English  45 
Installation instructions
Installing a 4-wire power cord
WARNING
The neutral wire of the supply circuit must be connected to the neutral terminal located in 
the lower center of the terminal block. The power leads must be connected to the lower 
left and the lower right terminals of the terminal block. The grounding lead (Green) must 
be connected to the frame of the range with the ground plate and the ground screw.
Ground strap
Ground plate
Ground 
screw
Neutral 
terminal
Ground wire 
(Green)
White
Black
Red
Black
White
Red
1.  Remove the 3 lower terminal screws 
from the terminal block. Remove the 
ground screw and ground plate and 
retain them.
2.  Cut and discard the ground strap. Do 
not discard any screws.
3.  Insert the one ground screw into the 
power cord ground wire terminal ring, 
through the ground plate, and into the 
frame of the range.
4.  Insert the 3 terminal screws (removed 
earlier) through each power cord 
terminal ring and into the lower 
terminals of the terminal block. Be 
certain that the center wire (white/
neutral) is connected to the center 
lower position of the terminal block. 
Tighten screws securely into the 
terminal block.
Install_NY9900M_PRORANGE_DOP48M96DLM_DA_DG68-00936A-00_EN+MES+CFR.indb 45 2017-05-12  7:36:51