Installation Instructions
Installing the Flexible Conduit, cont.
Installing a 4-wire conduit
• Aluminum building wire may be used but it must be rated for the correct amperage and
voltage. Connect wires according to this Step 4 depending on the number of wires.
• Wire used, location and enclosure of splices, etc., must conform to good wiring practices and
local codes.
Ground strap
Ground plate
Red
Neutral
terminal
Ground wire (Green)
Wire
tips
White
Black
Red
1. Loosen the 3 lower screws on the terminal
block. Remove and retain the ground screw
and ground plate.
2. Cut and discard the ground strap. Do not
3.
4.
5.
6.
discard any screws.
Insert the ground bare wire tip between the
range frame and ground plate (removed
earlier), and secure it with the ground screw
(removed earlier).
Insert the wire (white/neutral) tip through
the bottom center of the block opening.
Insert the left and right wire tips into their
respective block openings.
Tighten the screws to 35 – 50 in.-lbs.(Any
tighter may damage the wires.)
Black
White
Gas Connection
WARNING
• Turn off the gas-supply valve, and turn off power to the range at the circuit breaker or fuse box
before connecting the gas line.
• Do not apply excessive pressure when tightening gas connections and fittings.
• Do not use Teflon tape or plumber’s putty on gas flex-line connections.
• Maximum gas-supply pressure to the regulator must not exceed ½ psi (pounds per
square inch)
or 3.5 kPa.
• The range and shut-off valve must be disconnected from the gas-supply piping for pressure
testing that exceeds ½ psi (3.5 kPa).
• The range must be isolated from the gas-supply piping by closing the shut-off valve for pressure
testing at or below ½ psi (3.5 kPa).
•
Check all gas lines for leaks as instructed to avoid fire/explosions hazard. Do not check for leaks
with a flame.
NOTE
The gas-pressure regulator is factory set for the type of gas used with the range. To verify that the
range is compatible with the available gas, see the rating label (oven left door trim). Consult your
dealer if the range is incompatible with the supplied gas.