Installation Manual
Table Of Contents
English 25
InstalInstallation lation InstructionInstructionss
Installing the Flexible Conduit
Remove the conduit connection plate from the rear of the drawer body, and flip it as shown.
(Use the 1⅛" hole.)
1⅛" 1⅜"
1⅛"
1⅜"
1. Prepare the conduit cord (Figure 1).
2. Install the conduit cord (Figure 2).
Conduit connection plate
Strain relief
Ring
Body
Figure 2
1"
3½"
⅜" 1"
3½"
3 wire 4 wire
Knockout surface
Figure 1
⅜"
Conduit installations: Insert the strain relief (not included) i
n the 1⅛"conduit hole, thread the
conduit cord through
th
e body of the strain relief, and fasten th
e ring, th
en reinstall th
e bracket.
Installing a 3-wire Conduit
• Aluminum building wire may be used but must be rated for the correct amperage and
voltage. Connect wires according to Step 4 depending on the number of wires.
• Wire used, location/enclosure of splices, etc.
, must follow good wiring practices and local
codes.
White
Black
Red
Ground strap
Neutral terminal
Wire tips
Red
White
Black
1.
2.
3.
Loosen the three lower screws on the terminal
block.
Insert the white/neutral bare wire tip through the
bottom-center block opening. (Some models: the
wire inserted through the ground-strap opening
into the bottom-center block opening.)
Insert the left and right wire tips into their
respective block openings.
4. Tighten the screws to 35 – 50 in.-lbs.(Any tighter
may damage the wires.)