Installation Requirements
Gas Requirements
Provide Adequate Gas Supply
This oven's installation must conform to local codes or, in their absence, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54.
This range's cooktop is designed to operate at a manifold pressure of 5 in. (13 cm) of water column
for natural gas/natural gas at high altitude (NG-H) or 10 in. (25.4 cm) of water column for LP
(propane)/LP at high altitude (LP-H).
Verify that the oven is right for the provided gas service.
When verifying regulator function, inlet pressure must be at least 1 in. (2.5 cm) greater than the
operating (manifold) pressure as given.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Minimum Manifold Pressure Minimum Gas Supply Pressure**
Natural Gas
5” Water Column
6” Water Column
*The gas supply pressure for testing the regulator setting shall be at least 1" water column (249 Pa) above the
specified manifold pressure; **Maximum gas supply pressure for all models: 1/2 psi.
LP (propane) Gas
10” Water Column
11” Water Column
NOTE
The pressure regulator at the inlet of the cooktop manifold must stay in the supply line whether
or not natural or LP gas is used.
Use only the range's regulator, which must be installed in the gas line that runs from the
cooktop gas inlet to the gas shut-off valve.
An external manual shut-off valve must be installed between the gas inlet and range for turning
on/off gas to the appliance.
Ensure the connectors are installed by a qualified installer.
To avoid leaks and personal injury, never install used connectors on a new product. Use only
new, flexible connectors.
Special Gas Requirements (gas models sold in Massachusetts)
WARNING
Gas leaks may occur in your system, creating a hazardous condition. Such leaks may not be
detected by smell alone; thus, gas suppliers recommend installing a UL-approved gas detector
per manufacturer specifications.
The range must be installed by a plumber or gas fitter certified by the State of Massachusetts.
A T-handle manual gas valve MUST be installed in the gas-supply line to your range.
If using a flexible gas connector, multiple lines must not be connected in series.