Installation Manual
Table Of Contents
English 17
Installation Requirements
Gas and Electrical Service
• See below for the recommended location of the gas inlet and electrical junction box/receptacle.
Existing utilities may be used if they are compatible with this range. Check local building codes
for allowed gas-valve locations.
• An external manual shut-off valve must be installed between the gas inlet and range so the
range's gas supply can be turned on/off. Installation must allow access to the gas shut-off valve
when the unit is installed and access to the remote circuit-breaker panel/fuse box without
moving the range.
• The gas-supply piping and shut-off valve, and the electrical junction box/receptacle must be
located so as not to interfere with the range when it is installed.
• The junction box and gas-shut off valve must be located so the range can be pulled out for
service without being disconnected.
G
E
D
F
Recommended
position for
Gas stub
Recommended
position for
electrical outlet
Model D E F G
DOP36M94D
8 7/8"
(22.5 cm)
6 5/8"
(16.8 cm)
11 3/16"
(28.4 cm)
24 1/4"
(61.6 cm)
DOP48M96D
5 1/2"
(13.9 cm)
6 5/8"
(16.8 cm)
8 1/8"
(20.6 cm)
26 5/8"
(67.6 cm)