Installation Guide
17English
Installation Requirements
Gas and Electrical Service
•  See below for the recommended location of the gas inlet and electrical junction box/receptacle. Existing 
utilities may be used if they are compatible with this range. Check local building codes for allowed gas-
valve locations.
•  An external manual shut-off valve must be installed between the gas inlet and range so the range's gas 
supply can be turned on/off. Installation must allow access to the gas shut-off valve when the unit is in-
stalled and access to the remote circuit-breaker panel/fuse box without moving the range.
•  The gas-supply piping and shut-off valve, and the electrical junction box/receptacle must be located so as 
not to interfere with the range when it is installed.
•  The junction box and gas-shut off valve must be located so the range can be pulled out for service without 
being disconnected.
Model D E F G
DOP36M86D* 8 7/8" (22.5 cm) 6 5/8" (16.8 cm) 11 3/16" (28.4 cm) 24 1/4" (61.6 cm)
DOP48M86D* 5 1/2" (13.9 cm) 6 5/8" (16.8 cm) 8 1/8" (20.6 cm) 26 5/8" (67.6 cm)