LP Conversion Guide
2. Converting the surface burners
The range comes with low-altitude LP conversion kits.
The kit contains 16 burner orices. Fourteen of these
16 orices are sized and color-coded for surface burner
use. The remaining 2 orices are for the bake and broil
oven burners. Use the following charts to properly size
and replace the orices:
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location BTU Rate Orice size [mm]
LF 16500 In : 0.46 / Out : 0.78 (2 pcs)
LR 14500 In : 0.46 / Out : 0.74 (2 pcs)
CF 14500 1.12
CR 14500 1.12
RR 14500 In : 0.46 / Out : 0.74 (2 pcs)
RF 16500 In : 0.46 / Out : 0.78 (2 pcs)
BAKE 23000 1.4
BROIL 14500 1.12
115
Orice markings:
115 – Denotes 1.15 mm orice size
opening.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location BTU Rate Orice size [mm]
LF 22000 In : 0.85 / Out : 1.40 (2 pcs)
LR 16000 In : 0.70 / Out : 1.17 (2 pcs)
CF 16000 1.78
CR 16000 1.78
RR 16000 In : 0.70 / Out : 1.17 (2 pcs)
RF 22000 In : 0.85 / Out : 1.40 (2 pcs)
BAKE 25000 2.34
BROIL 18000 1.90
180
Orice markings:
180 – Denotes 1.80 mm orice size
opening.
A. Remove the surface burner grates.
B. Lift off the surface burner caps and the surface
burner heads from the surface burner manifold cups.
C. Using a 9/32˝ or 7 mm nut driver, remove the burner
orice from the bottom of each manifold cup.
NOTE
Keep these orices and note their positions for
future conversion back to natural gas.
LR-OUT (PUR)
IN (GRAY)
LF-OUT (NAVY)
IN (GRAY)
CR (ORG)
CF (ORG)
RR-OUT (PUR)
IN (GRAY)
RF-OUT (NAVY)
IN (GRAY)
D. Identify the proper orice by orice size and color
code for each of the surface burners.
E. Install the proper orices in each of the burner
manifold cups as shown above. Tighten with a 9/32˝
or 7 mm nut driver. Do not overtighten.
NOTE
Any other placement of orices could result in
dangerous operating conditions and/or poor cooking
results.
F. Replace the surface burner heads and caps in the
same location from which they were removed. The
burner heads should be at on top of the manifold
cups and the caps should be at on top of the burner
heads to ensure proper, safe operation.
3. Converting the oven burners
WARNING
The following adjustments must be made before
turning on the gas to the oven burners. Failure to
do so could result in death and/or serious personal
injury due to high ames and toxic fumes.
The oven has a bake (lower) and a broil (upper) oven
burner. Both burners require the orices to be changed.
See the charts in column 2 for the proper orice usage.
To replace the bake (lower) burner orice:
A. Remove the two screws from the back of the cavity
oor. Lift back to clear the front edge and lift out the
cavity oor.
B. Remove three screws from the front of the bracket
bake-spreader.
C. Lift front the bracket bake spreader and lift out the
bracket-bake spreader.
D. Lift up the burner bake from the bake burner box.
E. Using a 9/32˝ or 7mm nut driver and an adjustable
wrench, hold the gas tting with the wrench and
remove the bake oven burner orice from the center
of the lower gas tting.
IMPORTANT SAFETY INFORMATIONS
WARNING
The following information is intended for use by
persons possessing adequate electrical, electronics,
and mechanical backgrounds and experience. Lack
of proper background and experience during any
repair of a major appliance could result in death,
personal injury, and/or property damage. The
manufacturer or seller cannot be responsible for the
interpretation of this information, nor can it assume
any liability in connection with its use.
• Disconnect the electrical power to the appliance
before servicing.
• Shut off the gas supply to the appliance before
servicing.
• Reconnecting all grounding devices before
reconnecting the electrical power and opening the
gas supply to the appliance.
• All electrical components in this appliance are
grounded. All grounding wires, screws, straps,
nuts, and/or washers must be replaced to their
original position and properly fastened.
• LP conversion must be performed by a qualied
installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction.
Failure to follow ALL instructions could result
in serious injury or property damage. The
qualied agency performing this work assumes
responsibility for the conversion.
• Know the location of the gas shut-off valve and
how to shut it off if necessary.
• Do not operate the cooktop surface burners or
oven burners of this range when using LP gas
before converting the pressure regulator and
burner orices for LP gas use. Failure to do so
could cause high ames and toxic fumes which can
result in serious injury.
• Do not mix up or substitute LP gas burner
orices during the conversion process. Improper
orice placement will affect burner and cooking
performance and could result in personal injury
and/or product damage.
LP GAS (PROPANE) CONVERSION
1. Converting the pressure regulator
The regulator is located in the lower, left-hand corner of
the back panel.
A. Locate the pressure regulator on the lower, left hand
of the back panel. The pressure regulator can be
seen and accessed through the square hole of the
back panel.
B. Using at driver, turn the dual purpose orice
counterclockwise to remove from the pressure
regulator.
C. Completely remove the orice and reinstall it on the
opposite side of the spud.
Brass Cap
Dual-Purpose
Orice
Shut-Off
Lever
Flip Orice
to change
application
size.
Pressure
Regulator
NG
LP
D. Reinstall the orice in the pressure regulator so the
large, open LP gas end is exposed. Tighten the spud
using at screw driver. Do not overtighten.
E. Make sure the gas shut-off lever on the side of the
pressure regulator is in the open position.
Mini-Manual_DOP36M96GLM_AA_DG68-01108C-01_EN.indd 1 2019-06-25 1:21:43