16 English
Self-diagnosis
Self-diagnosis
Barrier
WARNING
When inserting the oven, use caution not to
deform or damage the barrier underneath.
Self-diagnosis
Temp sensor & Heater check
1. After connecting the power, check if the display works properly.
2. Remove all accessories (Gliding Rack, Flat-Rack, Smart Divider...etc.) from
inside of the oven cavity.
3. You cannot proceed with self-diagnosis if the oven cavity is hot or the door is
open.
• In this case, “Hot or door” message appears on the display.
4. To start self-diagnosis, press both Hidden Keys simultaneously for 5 seconds
and select install test button.
• Refer to the table below for the hidden keys for each model.
• Self-diagnosis takes approximately 6-7 minutes.
Model DOB30P977DS
Control panel
Hidden Key UPPER + LOWER
Model DOB30P977SS
Control panel
Hidden Key SETTING + RESERVOIR
Install_DOB30P977_DG68-01308A-00_EN+MES+CFR.indb 16 2020-06-24 �� 10:12:37