Installation Instructions Modernist® Island (Ceiling Mount) Range Hood DHD36M967IM, DHD36M967IS, DHD48M977IM, DHD48M977IS Approved for use with all Dacor® ranges and cooktops. Part No. 113850 Rev.
TABLE OF CONTENTS Important Safety Instructions..........................................................1 Important Information........................................................................... 1 General Safety Precautions................................................................... 1 Installation Specifications ................................................................2 Performance Specifications..................................................................
IMPORTANT SAFETY INSTRUCTIONS Important Information General Safety Precautions • The Important Safety Instructions and warnings in this manual cannot cover all possible issues. Use caution and common sense when installing the hood. • Contact Dacor Customer Assurance about issues you cannot resolve. (See previous page for contact info.
INSTALLATION SPECIFICATIONS Performance Specifications Product Dimensions All Models IMPORTANT: The installed hood-bottom-to-cook-surface distance must be at least 26" (66.0 cm). This distance may increase depending on the cooking unit. (See the cooking unit's Installation Instructions for details.) Blower 600 CFM* (1 blower); 1200 CFM* (2 blowers) Blower Speeds 4 DHD36 Lights 120 Vac, 7.
INSTALLATION SPECIFICATIONS Planning the Location WARNING • Observe all governing regulations during planning/installation. Contact the local building department for details. • To avoid injury and property damage from the hood falling, use only the provided mounting bracket. • Situate the hood for convenient access, and verify that power can be supplied to the site. • The selected model must be at least as wide as the cooktop. • Install the hood and cooking unit so they can be removed for service.
INSTALLATION INSTRUCTIONS Verifying Package Contents Uncrate the hood, and verify that all parts are present. FF Chassis FF Baffle filters (DHD36: 2 ea.; DHD48: 3 ea.) FF Chimney framework (2 pcs) FF Chimney covers (2 pcs—upper, with grates; lower) FF Ceiling plate FF Mounting hardware (hex nuts, washers: 4 ea.; plastic anchors: 4; 1 1/2" Phillips-head screws: 4; safety screws: 4) FF Stainless-steel cleaner (1 two-oz. bottle) FF Product literature (Installation Instructions, User Manual).
INSTALLATION INSTRUCTIONS Attaching the Hood to the Ceiling Attaching the Chimney Structure 1. Align the 4 screw holes on the base chimney piece with the threaded studs on the chassis superstructure. Base Chimney Piece Washer and Nut (4 ea.) Hood Chassis Threaded Stud (4) 2. Place a washer and nut on each stud, and tighten the nuts. 3. (Keeping the cabling within the notch in the ceiling plate) Place a length of ducting over the collar on the fan outlet, and secure the ducting with a hose clamp. 4.
INSTALLATION INSTRUCTIONS Verifying Function 1. Switch on power at the circuit-breaker panel or fuse box. 2. If the control panel is not lit, remove the filters, and turn on the main power switch (behind the filters inside the hood; install the filters. 3. Tap the light key; verify that all lights come on. 4. Tap the light key to turn the lights off. 5. Tap blower-speed increase ( + ); verify that one light appears on the indicator and that the blower is on low speed. 6. Quickly tap + three times.
WIRING DIAGRAM 7
NOTES 8
NOTES 9
Dacor ∙ 14425 Clark Avenue, City of Industry, CA 91745 ∙ Phone: (800) 793-0093 ∙ Fax: (626) 403-3130 ∙ www.dacor.