Installation guide

ENGLISH
Recommended
Minimum
kW
Rating
on
Circuit
protection
Wire
size
serial
plate
in
amperes
(AWG)
0-4.8
20
12
4.9-6.9
30
10
7.0-9.9
40
8
10.0-114.9
50
8
12.0-14.9
60
6
Be
sure
your
appliance
is
properly
installed
and
grounded
by
a
qualified
technician.
Ask
your
dealer
to
recommend
a
qualified
technician
or
an
authorized
repair
service.
This
cooktop
does
not
require
a
neutral
connection.
If
the
cooktop
Is
to
be
completely
enclosed
In
a
cabinet,
feed
the
cooktop
cable
through
the
opening
in
the
cabinet.
Make
the
electrical
connection
following
the
appropriate
steps
for
your
installation.
This
appliance
is
manufactured
with
a
green
ground
wire
connected
to
the
cooktop
chassis.
After
making
sure
that
the
power
has
been
turned
off,
connect
the
flexible
conduit
from
the
cooktop
to
the
junction
box
using
a
ULL.
listed
conduit
connector.
Figures
13
and
14
and
the
instructions
provided
below
present
the
most
common
way
of
connecting
the
cooktops.
Your
local
codes
and
ordinances,
of
course,
take
precedence
over
these
instructions.
Complete
electrical
connections
according
to
local
codes
and
ordinances.
Ay|
DANGER
Risk
of
Electric
Shock,
frame
grounded
to
neutral
of
appliance
through
a
link.
Grounding
through
the
neutral
conductor
is
prohibited
for
new
branch-circuit
installations
(1996
NEC);
mobile
homes;
and
recreational
vehicles,
or
in
an
area
where
local
codes
prohibit
grounding
through
the
neutral
conductor.
3u\MVire
branch
circuit
Where
local
codes
allow
the
connection
of
ground
wire
from
the
cooktop
to
the
branch
circuit
neutral
wire
(gray
or
white
colored
wire)
proceed
as
follows
(see
figure
13).
1.
If
local
codes
permit,
connect
the
green
GROUND
wire
from
the
cooktop
to
the
branch
circuit
neutral
wire
(gray
or
white
colored
wire).
2.
Connect
the red
and
black
leads
from
the
cooktop
to
the
corresponding
leads
in
the
junction
box.
3-WIRE
CABLE
FROM
POWER
SUPPLY
RED
WIRES
JUNCTION
BOX
BARE
OR
GREEN
WIRES
3-WIRE
CABLE
FROM
COOKTOP
ULL.-OR
CSA-LISTED
CONDUIT
CONNECTOR
Where
local
codes
permit
connecting
the
frame-ground
conductor
to
the
neutral
(white)
junction
box
wire.
(Not
used
for
Canadian
installations)
INST
031-2
Figure
713.
4-Wire
branch
circuit
Refer
to
figure
14:
4.
Connect
the
green
ground
wire
from
the
cooktop
to
the
ground
wire
in
the
junction
box
(bare
or
green
colored
wire).
2.
Connect
the red
and
black leads
from
the
cooktop
to
the
corresponding
leads
in
the
junction
box.
3.
Connect
the
white
wire
from
the
cooktop
to
the
neutral
(gray
or
white)
wire
in
the
junction
box.
4.
Terminate
and
insulate
the
neutral
(gray
or
white
colored
wire)
in
the
junction
box.
RED
WIRES
JUNCTION
BOX
WHITE
WIRE
BARE
OR
GREEN
WIRES
3-WIRE
CABLE
FROM
COOKTOP
TWIST-ON
CONNECTOR
BLACK
WIRES
U.L.-OR
CSA-LISTED
CONDUIT
CONNECTOR
INST
032-2
Figure
14.