LCD MONITOR User’s Guide FS-A4206F/FS-A4206C
INFORMATION TO USE : This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against interference. This monitor can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may interfere with other radio communications equipment. There is no gguarantee that interference will not occur in a particular p installation.
Table of contents 1. Part--------------------------------------------------------------------------------------------------- 1 2. Product drawing----------------------------------------------------------------------------------- 2 3. Monitor Connection----------------------------------------------------------------------------- 3 4. Function key--------------------------------------------------------------------------------------- 5 5.
LCD MONITOR Parts 42” LCD Monitor USER MANUAL DVI-HDMI Cable (Option) 1 General Specification AC power extension Cable(Option) Serial Cable (Option)
LCD MONITOR Product drawing g Unit : mm 2
LCD MONITOR Monitor Connection ● FS-A4206C 1. 1 2. 3. 4. 5. 6. AC on/off / ff Switch S h AC Inlet. 29 Pin DVI in connector 29 Pin DVI Out connector 15 Pin VGA connector 9 Pin RS-232 connector ● FS-A4206F 1. 2. 3. 4. 3 AC on/off Switch AC Inlet.
LCD MONITOR Power source connection g cable connection Signal ● DVI In,Out put To the AC inlet connector ● AC Input ● VGA Analog ● RS-232 ● AC on/off switch 1. 2. 3. 4. Use 220V or 110V. Connect the DVI Cable to the monitor. Power on the monitor. Done.
LCD MONITOR Function key y An 8 button keypad, located in rear side of the display, allows the user to make adjustments to various display parameters using the On Screen Display(OSD) system.
LCD MONITOR 5. PLUS(+) : With OSD deactivated, Hot key of the contrast control and increases the contrast. With OSD activated, enter sub menu and increases the adjustment of the selected. 6. MINUS(-) : With OSD deactivated, Hot key of the contrast control and decreases the contrast. With OSD activated, decreases the adjustment of the selected function. 7.INPUT : With OSD deactivated, you can see the kind of displayed source on lower right of the screen. 8.
LCD MONITOR OSD adjust j PICTURE BRIGHTNESS Increase or decrease the brightness. (Range : 0 ~ 100) CONTRAST Increase or decrease the contrast. (Range : 0 ~ 100) BACKLIGHT Increase or decrease the backlight. (Range : 0 ~ 100) COLOR TEMP MODE Change the color temperature mode : 6500K, 7200K, 9300K, USER When USER is selected, a sub-menu displays allowing the user to adjust the RED, GREEN or BLUE balance. RED Red balance – Only works on the USER mode.
LCD MONITOR IMAGE IMAGE Change the image size : FILL ASPECT, FILL ALL, ONE TO ONE SHARPNESS Set the sharpness of the image. (SOFTEST, SOFT, NORMAL, SHARP, SHARPEST) RESET SETTINGS Restore all the OSD values to factory out-going status. UNIT ID Change the unit identification. (Range : 1 ~ 9) OSD SETUP LANGUAGE Change the OSD Language. (8 languages – English, German, French, Spanish, Italian, Chinese, Japanese, Korean) OSD COLOR Adjust transparency of OSD background.
LCD MONITOR Standard signal g table PC Supported mode Resolution Horizontal Frequency(KHz) Vertical Frequency(Hz) Clock Frequency(MHz) 640x480@60Hz @ 31.469 59.940 25.175 800x600@50Hz 31.500 50.000 35.4375 800x600@50Hz 37.879 60.317 40.000 800x600@75Hz 46.875 75.000 49.500 1024x768@60Hz 48.363 60.004 65.000 1280 720@50H 1280x720@50Hz 37 500 37.500 50 000 50.000 74 250 74.250 1280x720@60Hz 45.000 60.000 74.250 1280x720@100Hz 75.000 100.000 148.500 1280x720@120Hz 90.
LCD MONITOR Signal g Connector pin p assignments g DVI In,Out (DVI-I 29Pin) Pin No. Assignment Pin No.
LCD MONITOR VGA (D-SUB (D SUB 15Pin) 15Pi ) Pin No. Assignment Pin No. Assignment 1 Red 9 No Connection 2 Green 10 Ground-Sync 3 Bl Blue 11 G Ground d 4 Ground 12 DDC Data 5 DDC 5V Standby Cable Connection check 13 H.Sync 6 G Ground-Red dR d 14 VS V.
LCD MONITOR Specification p Model LCD PANEL Synchronization Power Consumption Power Approval Marks Energy Dimension FS-A4206F Type A-si TFT Active matrix Display area 930.4(H) mm X 523.26(V) mm Maximum Resolution 1920X1080@120Hz Pixel pitch 0.4845(H)mm X 0.4845(V)mm Display colors 1073.7M (RGB 10-bit data) Contrast Ratio(Typ.) 4000:1 Viewing Angle(Typ.) 89/89/89/89 Response Time(Typ.) 5ms Luminance(Typ.) 500cd/m2 Horizontal Frequency 135.
LCD MONITOR Model LCD PANEL Synchronization Power Consumption Power FS-A4206C Type A-si TFT Active matrix Display area 930.4(H) mm X 523.26(V) mm Maximum Resolution 1920X1080@120Hz Pixel pitch 0.4845(H)mm X 0.4845(V)mm Display colors 1073.7M (RGB 10-bit data) Contrast Ratio(Typ.) 4000:1 Viewing Angle(Typ.) 89/89/89/89 Response Time(Typ.) 5ms Luminance(Typ.) 500cd/m2 Horizontal Frequency 135.6 KHz Vertical Frequency 120 Hz Maximum 120W Standby Mode Under 0.
LCD MONITOR Safety y instructions Operator Safety Instructions For your safety, please read these safety instructions completely before you connect the equipment to the power source. The information in this summary is intended for operators. Carefully observe all warnings, precautions and instructions both on the apparatus and in these operating instructions. instructions Retain this manual for future reference.
LCD MONITOR Power Connection P C ti and d Hazardous H d Voltage V lt The product may have hazardous voltage inside. Never attempt to open this product, or any peripherals connected to the product, where this action requires a tool. This product should always be powered from an earthed power outlet. Never connect attached power supply cord to other products.
LCD MONITOR Warning g When connecting to/disconnecting from a power outlet, push/pull on the plug itself. Never pull the cord, in order to prevent fire caused by a short. In order to prevent electric shock, do not connect/disconnect the plug with wet or moist hands. If you see smoke or smell something burning, stop using the unit, switch off the power, pull out the plug, and then contact your local service station. To prevent fire, do not connect a large number of equipments in a single line.
General Specification