System information
3. Scenario 3 – L3 Overlay: 1 Unified Switch + 1 AP + 1 Remote
AP
The diagram in this section shows a network configuration with a D-LINK Unified Switch
connected to an L3 Device/Router. One AP is connected to the D-LINK Unified Switch, and the
other is connected to the L3 device. Both APs are managed by the D-LINK Unified Switch.
This scenario uses L3 tunneling so that a client that associated with AP1 initiates an audio
conversation and roams to a different subnet. In the process, the client is disassociated with AP1
and gets associated with AP2 maintaining the audio conversation.
This scenario is especially useful for you to setup a demo in customers’ existing network with
little change to customers’ network configuration.
The objectives for this scenario include the following:
• To know how to setup the L3 tunneling (L3 Tunneling must be used since the APs are on
different IP subnets and there is not a L2 path between the APs for the WLAN Network
data).
• To know how to manage the remote AP and the most practical deployment into
customers’ existing networks.
In this scenario, the L3 device is part of the customer network. The L3 device must meet the
following minimum requirements:
• One network to connect to the Unified Switch (in this scenario, the network is
172.17.5.0/24)
• One network to connect to AP2 (in this scenario, the network is 172.17.6.0/24)
• DHCP server in the AP2 network for AP and wireless client addresses
Unified Switch1
AP1
Network IP: 10.90.90.90
Loopback: 192.168.10.254
L3 Tunnel: 192.168.250.254
CL1
FTP Server
Audio/Video Server
192.168.20.x
192.168.250.x
SSID:
L3-Tunnel: 192.168.250.x
AP2
L3 Device
Across L3 Network
172.17.5.0/24
172.17.6.0/24
Seamless Roaming
172.17.6.x