System information

381
DWS-1008 CLI Reference Guide
D-Link Systems, Inc.
System Log Commands
Syntax: set log {buffer | console | current | server ip-addr | sessions | trace} [severity
severity-level] [enable | disable]
set log server ip-addr [severity severity-level [local-facility facility-level]] [enable |
disable]
buffer Sets log parameters for the log buffer in nonvolatile storage.
console Sets log parameters for console sessions.
current Sets log parameters for the current Telnet or console
session. These settings are not stored in nonvolatile
memory.
server ip-addr Sets log parameters for a syslog server. Specify an
address in dotted decimal notation.
sessions Sets the default log values for Telnet sessions. You can set
defaults for the following log parameters:
• Severity
• Logging state (enabled or disabled)
To override the session defaults for an individual session,
type the set log command from within the session and use
the current option.
trace Sets log parameters for trace files.
severity
severity-level
Logs events at a severity level greater than or equal to the
level specified. Specify one of the following:
emergency - The switch is unusable.
alert - Action must be taken immediately.
critical - You must resolve the critical conditions. If the
conditions are not resolved, the switch can reboot or
shut down.
error - The switch is missing data or is unable to form a
connection.
warning - A possible problem exists.
notice - Events that potentially can cause system
problems have occurred. These are logged for diagnostic
purposes. No action is required.
info - Informational messages only. No problem exists.
debug - Output from debugging.