User`s manual

84
DWS-1008 User’s Manual
D-Link Systems, Inc.
Conguring and Managing Ports and VLANs
4. Congure port 5 and 6 as wired authentication ports and verify the conguration change.
Type the following commands:
DWS-1008# set port type wired-auth 5
success: change accepted
DWS-1008# show port status
Port Name Admin Oper Config Actual Type Media
=============================================================
1 mgmt up up auto 100/full network 10/100BaseTx
2 finance up up auto 100/full ap 10/100BaseTx
3 accounting up up auto 100/full ap 10/100BaseTx
4 shipping up up auto 100/full ap 10/100BaseTx
5 lobby up up up auto 100/full wired auth 10/100BaseTx
6 conf_room1 up up auto 100/full wired auth 10/100BaseTx
7 backbone up down auto network
8 backbone up down auto network
5. Congure ports 7 and 8 as a load-sharing port group to provide a redundant link to the
backbone, and verify the conguration change. Type the following commands:
DWS-1008# set port-group name backbonelink port 7,8 mode on
success: change accepted.
DWS-1008# show port-group
Port group: backbonelink is up
Ports: 7,8
6. Add port 1 to the default VLAN (VLAN 1), congure a VLAN named roaming on ports 2
and 3, and verify the conguration changes. Type the following commands:
DWS-1008# set vlan default port 1
success: change accepted.
DWS-1008# set vlan 2 name roaming port 2,3
success: change accepted.
DWS-1008# show vlan cong
Admin VLAN Tunl Port
VLAN Name Status State Affin Port Tag State
--------------------------------------------------------------------------------------------------------------
1 default Up Up 5
1 none Up
2 roaming Up Up 5
5 none Up
6 none Up