User manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 Installation
- Chapter 3 Quick setup
- Chapter 4 Configuration
- Chapter 5 Advanced operations
- Chapter 6 Troubleshooting

120
INFO BBM status good Battery backup module is good
INFO BBM status
charging
Battery backup module is charging
WARNING BBM status fail Battery backup module is failed
INFO BBM enabled Battery backup feature is <string>.
INFO BBM inserted Battery backup module is inserted
INFO BBM removed Battery backup module is removed
JBOD events
Level Type Description
INFO PD upgrade started JBOD <name> PD [<string>] starts upgrading firmware
process.
INFO PD upgrade
finished
JBOD <name> PD [<string>] finished upgrading firmware
process.
WARNING PD upgrade failed JBOD <name> PD [<string>] upgrade firmware failed.
INFO PD freed JBOD <name> PD <slot> has been freed from RG <name>.
INFO PD inserted JBOD <name> disk <slot> is inserted into system.
Warning PD removed JBOD <name> disk <slot> is removed from system.
ERROR HDD read error JBOD <name> disk <slot> read block error
ERROR HDD write error JBOD <name> disk <slot> write block error
ERROR HDD error JBOD <name> disk <slot> is disabled.
ERROR HDD IO timeout JBOD <name> disk <slot> gets no response
INFO JBOD inserted JBOD <name> is inserted into system
WARNING JBOD removed JBOD <name> is removed from system
WARNING SMART T.E.C JBOD <name> disk <slot>: S.M.A.R.T. Threshold Exceed
Condition occurred for attribute <string>
WARNING SMART fail JBOD <name> disk <slot>: Failure to get S.M.A.R.T
information
INFO PD dedicated spare Assign JBOD <name> PD <slot> to be the dedicated spare
disk of RG <name>.
INFO PD global spare Assign JBOD <name> PD <slot> to Global Spare Disks.
ERROR Config read fail Config read error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
ERROR Config write fail Config write error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
WARNING PD read error Read error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
WARNING PD write error Write error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
INFO PD scrub started JBOD <name> PD <slot> starts disk scrubbing process.
INFO PD scrub completed JBOD <name> PD <slot> completed disk scrubbing process.
WARNING PS fail Power Supply of <string> in JBOD <name> is FAIL
INFO PS normal Power Supply of <string> in JBOD <name> is NORMAL
WARNING FAN fail Cooling fan of <string> in JBOD <name> is FAIL
INFO FAN normal Cooling fan of <string> in JBOD <name> is NORMAL
WARNING Volt warn OV Voltage of <string> read as <string> in JBOD <name> is
WARN OVER
WARNING Volt warn UV Voltage of <string> read as <string> in JBOD <name> is
WARN UNDER
WARNING Volt crit OV Voltage of <string> read as <string> in JBOD <name> is
CRIT OVER
WARNING Volt crit UV Voltage of <item> read as <string> in JBOD <name> is
CRIT UNDER