User`s manual

Unpacking and Installation
Contact your dealer for correction of any LED problems before
proceeding.
The actual component tests immediately follow the LED tests.
A normal (no fault) result is signaled by a series of three cycles
of sequential flashing of the three LEDs, followed by a
quiescent state with all three LEDs dark.
If the self-test routine traps any component error, then
following the LED tests the self-test will halt and the LED’s will
continuously signal the error accordi ng to the following table.
In the event of any such error signal, contact your dealer for
correction of the faulty unit.
LED Name
Faulty
LPT1 LPT2 COM
Component
off off on/steady COM error
off off flashing Flash ID error
off on/steady off LPT2 error
off on/steady on/steady LAN Controller error
off on/steady flashing LAN Memory error
off flashing off
Parallel-2 Controller error
off flashing on/steady
EEPROM error
off flashing flashing Flash Protected
on/steady off off LPT1 error
on/steady off on/steady Timer INT error
on/steady off flashing LAN IO Base error
on/steady on/steady off RAM error
flashing off off Parallel-1 Controller error
flashing flashing off Flash erase/program error
flashing flashing flashing Need to reload firmware