User Manual

DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch
94
The fields that can be configured are described below:
Parameter Description
IP Address
Enter the RADIUS server’s IPv4 address here.
IPv6 Address
Enter the RADIUS server’s IPv6 address here.
Authentication Port
Enter the authentication port number used here. This value must
be between 0 and 65535. By default, this value is 1812. If no
authentication is used, use the value 0.
Accounting Port
Enter the accounting port number used here. This value must be
between 0 and 65535. By default, this value is 1813. If no
accounting is used, use the value 0.
Retransmit
Enter the retransmit value used here. This value must be between
0 and 20. By default, this value is 3. To disable this option, enter
the value 0.
Timeout
Enter the timeout value used here. This value must be between 1
and 255 seconds. By default, this value is 5 seconds.
Key
Enter the key, used to communicate with the RADIUS server,
here. This key can be up to 32 characters long.
Click the Apply button to accept the changes made.
Click the Delete button to remove the specified entry.
RADIUS Statistic
This window is used to view and clear the RADIUS statistics information.
To view the following window, click Security > RADIUS > RADIUS Statistic Settings, as shown below:
Click the Clear button to clear the information based on the selections made.
Click the Clear All button to clear all the information in this table.
Figure 8-6 RADIUS Statistic window