no timer {guard | hold-off | wtr}
Parameters
guard MILLI-SECONDS
(Optional) Specifies the guard timer in milliseconds. The value is
range from 10 to 2000.
hold-off SECONDS
(Optional) Specifies the hold-off timer in seconds. The value is
range from 0 to 10.
wtr MINUTES
(Optional) Specifies the WTR timer in minutes. The value is range
from 1 to 12.
status
Specifies to display the status of the ERP instances.
brief
Specifies to display the brief information of the ERP instances.
Default
The default guard timer is 500 milliseconds.
The default hold-off timer is 0 second.
The default WTR timer is 5 minutes.
Command Mode
G.8032 Profile Configuration Mode.
Command Default Level
Level: 15.
Usage Guideline
This command is used to configure timers for an ERP domain.
Example
This example shows how to configure guard timer to 700 for the profile campus.
Switch# configure terminal
Switch(config)# ethernet ring g8032 profile campus
Switch(config-g8032-ring-profile)# timer guard 700