Specifications

xStack
®
DGS-3600 Series Layer 3 Managed Gigabit Ethernet Switch
7
DGS-3650
Forty-eight 10/100/1000BASE-T ports
Four Combo SFP ports located to the right
One female DCE RS -232 DB-9 console port
LEDs for Power, Console, RPS, Link/Act/Speed and 10GE for each port
Stacking Module Numbered LED
Figure 1- 5. Front Panel of the DGS-3650
LEDs
The following table lists the LEDs located on models of the xStack
®
DGS-3600 Series switches along with their corresponding
description:
LED Indicator
Color
Status
Description
Power
Green
Solid
Power On
Dark Power Off
Console
Green Solid Console On
Dark
Console Off
RPS
Green Solid RPS in use
Dark RPS not in use or not present
Stacking LED
Green Numbered 1-12 Box ID of the Switch in the switch stack. This field will
read 1 for a switch in standalone mode. When the switch
in question is a master of a switch stack, the number of
the switch in the stack will be displayed, and the letter H
will flash alternatively with this number.
Port LEDs
(10/100/1000Mbps
ports)
Green Solid Denotes an active connection at 1000Mbps.
Blinking
Denotes data transfer at 1000Mbps.
Orange Solid Denotes an active connection at 10/100Mbps.
Blinking Denotes data transfer at 10/100Mbps.
Dark No Light Link Down
SFP Port LED
Green Solid Denotes an active connection at 1000Mbps.
Blinking Denotes data transfer at 1000Mbps.
Orange
(DGS-3612 and
DGS-3612G
only)
Solid Denotes an active connection at 100Mbps.
Blinking Denotes data transfer at 100Mbps.
Dark No Light Link Down
10GE Module
LEDs (Located on
the front panel)
Green Solid Denotes an active connection.
Blinking Denotes data transfer.
Dark No Light Link Down