Hardware Installation Guide Product Model: xStack ® DGS-3200 Series Layer 2 Managed Gigabit Ethernet Switch
_____________________________________________ Information in this document is subject to change without notice. © 2011 D-Link Corporation. All rights reserved. Reproduction in any manner whatsoever without the written permission of D-Link Corporation is strictly forbidden. Trademarks used in this text: D-Link and the D-LINK logo are trademarks of D-Link Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.
FCC Warning This equipment has been tested and found to comply with th e limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this m anual, m ay cause harm ful interfe rence to ra dio communications.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Table of Contents Intended Readers........................................................................................................................................................................... vi Typographical Conventions ...........................................................................................................................................................................vi Notes, Notices, and Cautions ........
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Introduction.................................................................................................................................................................................. 38 Logging onto the Web Manager....................................................................................................................................................................38 Web-based User Interface ..................................
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Intended Readers The DGS-3200 Series Hardware Installation Guide contains information for set up and management of the Switch. This manual is intended for network managers familiar with network management concepts and terminology. Typographical Conventions Convention Description [] In a command line, square brackets indicate an optional entry.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Notes, Notices, and Cautions A NOTE indicates important information that helps make better use of the device. A NOTICE indicates either potential damage to hardware or loss of data and tells how to avoid the problem. A CAUTION indicates a potential for property damage, personal injury, or death. Safety Cautions Use the following safety guidelines to ensure your own personal safety and to help protect your system from potential damage.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Do not push any objects into the openings of the system. Doing so can cause fire or el ectric shock by shorting out interior components. Use the product only with approved equipment. Allow the product to cool before removing covers or touching internal components. Operate the product only from the type of external power source indicated on the electrical ratings label.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances. Therefore, always install the stabilizers before installing components in the rack. After installing system/components in a rack, never pull more than one component out of the rack on its slide assemblies at one time.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Lithium Battery Precaution CAUTION: Incorrectly replacing the lithium battery of the Switch may cause the battery to explode. Replace this battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions. Protecting Against Electrostatic Discharge Static electricity can harm delicate components inside the system.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Section 1 Introduction Switch Description Features Ports Front-Panel Components LED Indicators Rear Panel Description Side Panel Description This manual describes the installation, maintenance, and configurations concerning the Switch. Switch Description D-Link's next-gene ration DGS-3200 Series is a high perform ancee member of the D-Link xStack® fam ily.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Features The list of features below highlights the significant features of the Switch. IEEE 802.3 compliant IEEE 802.3z compliant IEEE 802.3x Flow Control in full-duplex compliant IEEE 802.3u compliant IEEE 802.3ab compliant IEEE 802.1p Priority Queues IEEE 802.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Address table: Supports up to 8K (DGS-3200-10)/16K (DGS-3200-16 & DGS-3200-24) MAC addresses per device Supports a packet buffer of up to 1 Mbits (DGS-3200-10)/6 Mbits (DGS-3200-16 & DGS-3200-24) Port Trunking with flexible load distribution and fail-over function RADIUS Server failover Private VLAN IGMP Snooping support IGMP authentication support MLD Snooping support (MLD v1 and v2) IP-MAC-Port Binding (IMPB
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Ports Eight (DGS-3200-10) or 14 (DGS-3200-16) or 20 (DGS-3200-24) 10BASE-T/100BASE-TX/1000BASE-T Gigabit ports Two (DGS-3200-10 and DGS-3200-16) or four (DGS-3200-24) SFP Combo Ports (both 100FX and 1000BASE-X) Two (DGS-3200-10 and DGS-3200-16) or four (DGS-3200-24) 1000Mbps Copper Combo Ports (10BASE-T/100BASETX/1000BASE-T) One RS-232 DB-9 console port (DGS-3200-10 and DGS-3200-16) or one combo console with an RS-232 DB-9 conso
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Front-Panel Components The front panel o f th e Switch con sists of LED ind icators for Power, C onsole, and f or Link/Act for each port on the Switch including SFP port LEDs. A separate table below describes LED indicators in more detail. Figure 1- 1. Front Panel View of DGS-3200-10 Figure 1- 2.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch 10/100M 1000M xStack Link Act 1 Power Combo Console Console SD Card RPS SD Card DGS-3200-24 Figure 1- 6. LED Indicators for DGS-3200-24 LED Description Console This LED will blink green during the Power-On Self Test (POST). When the POST is finished, the LED goes dark. The indicator will light steady green when an active console link is in session via the RS-232 console port/RJ-45 connector (DGS-3200-24 only).
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Rear Panel Description The rear panel contains an AC power connector. Figure 1- 7. Rear panel view of DGS-3200-10 Figure 1- 8. Rear panel view of DGS-3200-16 Redundant Power Supply AC LINE 100-240 VAC 50-60 Hz 1.0A MAX Figure 1- 9. Rear panel view of DGS-3200-24 The AC power connector is a stand ard three-pronged connector that supports the power cord.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Side Panel Description The system heat vents located on each side dissipate heat. Do not block these openings. Leave at least 6 inches of space at the rear and si des of t he Switch for pro per v entilation. Be reminded th at witho ut pro per h eat d issipation and air circu lation, system components might overheat, which could lead to system failure or even severely damage components. Figure 1- 10.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Section 2 Installation Package Contents Installation Guidelines Installing the Switch without a Rack Rack Installation Power On Installing SFP Ports Package Contents Open the shipping carton of the Switch and carefully unpack its contents.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Installing the Switch without a Rack First, attach the rubber feet included with the Switch if installing on a desktop or shelf. Attach these cushioning feet on the bottom at each corner of the device. Allow enough ventilation space between the Switch and any other objects in the vicinity. Figure 2- 1. Prepare DGS-3200-10 for installation on a desktop or shelf Figure 2- 2.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Attaching Brackets to a Switch for Rack Mounting The Switch can be mounted in a standard 19" rack using the provided mounting brackets. Use the following diagrams as a guide. Figure 2- 4. Fasten mounting brackets on the DGS-3200-10 Figure 2- 5. Fasten mounting brackets on the DGS-3200-16 Figure 2- 6. Fasten mounting brackets on the DGS-3200-24 Fasten th e m ounting b rackets to the Sw itch using the screw s provided.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Mounting the Switch in a Standard 19" Rack Figure 2- 7. Installing the DGS-3200-10 in a rack Figure 2- 8. Installing the DGS-3200-16 in a rack Figure 2- 9.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Installing the Switch on a Wall The Switch can be mounted on a wall. Use the following diagrams and the installation steps on the next page as a guide. NOTE: Wall mounted ears only supported on DGS-3200-10 hardware versions A3 & B1. Figure 2- 10. Fasten mounting brackets on the back of the DGS-3200-10 to a wall NOTE: Wall mounted ears only supported on DGS-3200-16 hardware version A2. Figure 2- 11.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Wall Installation Steps Before beginning installation, simulate hanging the Switch by holding it against the wall with the wall mounting ears and marking the positions of the oval holes. These holes will be used with the wall mounting ears for installing the concrete sleeve anchors. Figure 2- 12. Illustration of each installation step 1.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Installing SFP Ports The Switch is equipped with SFP (Sm all Form Factor Portable) ports, which are to be used with fiber-optical transceiver cabling in order t o uplink va rious ot her networking devices for a gi gabit l ink that m ay span g reat distances.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Connect to RPS The DPS-200 is connected to the Master Switch using a 14-pin DC power cable. A standard, three-pronged AC power cable connects the redundant power supply to the main power source. Figure 2- 17. Connecting the DGS-3200-24 to the DPS-200 1. Insert one end of the 14-pin DC power cable into the receptacle on the switch and the other end into the redundant power supply. 2.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch External Redundant Power System The DPS-200 is a redundant power-supply unit designed to conform to the voltage requirements of the switches being supported. The DPS-200 can be installed into a DPS-900, or DPS-800 rack mount unit. CAUTION: The AC power cord for the Switch should be disconnected before proceeding with installation of the DPS-200.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch CAUTION: Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over, potentially resulting in bodily injury under certain circumstances. Therefore, always install the stabilizers before installing components in the rack. After installing components in a rack, do not pull more than one component out of the rack on its slide assemblies at one time.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Section 3 Connecting the Switch Switch to End Node Switch to Switch Connecting To Network Backbone or Server NOTE: All high-performance N-Way Ethernet ports can support both MDI-II and MDI-X connections. Switch to End Node End nodes include PCs outfitted with a 10, 100 or 1000 Mbps RJ-45 Ethernet Network Interface Card (NIC) and routers. An end node connects to the Switch via a twisted-pair UTP/STP cable.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Figure 3- 2. An example of a typical Switch, e.g. DGS-3200-24, connection Connecting To Network Backbone or Server The combo SFP ports and the 1000BASE-T ports are ideal for uplinking to a network backbone, server or server farm. The copper ports operate at a speed of 1000, 100 or 10Mbps in full or half duplex mode. The fiber-optic ports can ope rate at both 100Mbps and 1000Mbps in full duplex mode.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Section 4 Introduction to Switch Management Management Options Connecting the Console Port (RS-232 DCE) First Time Connecting to the Switch Password Protection SNMP Settings IP Address Assignment Connecting Devices to the Switch Management Options This system may be managed out-of-band through the console port on the front panel or in-band using Telnet. The user may also choose the web-based management, accessible through a web browser. 1.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Connecting the Console Port (RS-232 DCE/RJ-45) The DGS-3200-10 an d DG S-3200-16 provide an RS-23 2 ser ial por t that en ables a co nnection to a co mputer or t erminal f or monitoring and configuring the Switch. This port is a female DB-9 connector, implemented as a data terminal equipment (DTE) connection.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Once connected to the console, the screen below will appear on the console screen. This is where the user will enter commands to perform all the available management functions. The Switch will prompt the user to enter a user name and a password. Upon the initial connection, there is no user name or password and therefore just press enter twice to access the command line interface. Figure 4- 1.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Figure 4- 2. Initial screen, first time connecting to the Switch Press Enter in both the Username and Password fields. Then access will be given to enter commands after the c ommand prompt DGS-3200-10:4#. There is no initial username or password. Leave the Username and Password fields blank. NOTE: The first user automatically gets Administrator level privileges. At least one Admin-level user account must be created for the Switch.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch The sample below illustrates a successful creation of a new administrator-level account with the user name "newmanager". DGS-3200-10:4#create account admin newmanager Command: create account admin newmanager Enter a case-sensitive new password:******** Enter the new password again for confirmation:******** Success. DGS-3200-10:4# Figure 4- 3.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch them to the trap recipient (or network manager). Typical traps include trap messages for Authentication Failure, Topology Change and Broadcast\Multicast Storm. MIBs The S witch i n t he M anagement In formation B ase (MIB) st ores m anagement and counter i nformation. The Switch u ses t he standard MIB-II Management Information Base module. Consequently, values for MIB objects can be retrieved from any SNMPbased network management software.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Figure 4- 5. Assigning the Switch an IP Address In t he a bove e xample, t he S witch was assi gned a n IP address o f 10.24.22.100 with a su bnet m ask of 255.0.0.0. The sy stem message Success indicates t hat the comm and wa s e xecuted s uccessfully. The Switch can now be c onfigured and managed via Telnet and the CLI or via the Web-based management.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Section 5 Web-based Switch Configuration Introduction Logging onto the Web Manager Web-Based User Interface Introduction All software functions of the Switch can be managed, configured, and monitored via the embedded web-based (HTML) interface. Manage the Switch from remote stations anywhere on the network through a standard browser, such as Internet Explorer 5.5 or later, Netscape 8.0 or later, or Firefox 2.0 or later.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Web-based User Interface The user i nterface provides access to various Switch configuration and management windows, allows the user to performance statistics, and permits graphical monitoring of the system status. view Areas of the User Interface The figure below shows the user interface. Three distinct areas divide the user interface, as described in the table. Area 2 Area 1 Area 3 Figure 5- 2.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Web Pages When connecting to the management mode of the Switch with a Web browser, a login screen is displayed. Enter a user name and password to access the Switch's management mode.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Appendix A – Technical Specifications General Standards IEEE 802.3 10BASE-T Ethernet IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3ab 1000BASE-T Gigabit Ethernet IEEE 802.3z 1000BASE-T (SFP “Mini GBIC”) IEEE 802.1D/2004/Spanning Tree (802.1s, 802.1w) IEEE 802.1Q-2005 VLAN IEEE 802.1p Priority Queues IEEE 802.1X Network Access Control IEEE 802.3 Nway auto-negotiation IEEE 802.3ad Link Aggregation Control IEEE 802.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Physical and Environmental Internal Power Supply DGS-3200-10 & DGS-3200-16: AC Input: 100 – 240 VAC, 50-60 Hz DGS-3200-24: AC Input: 100 – 240 VAC, 50-60 Hz, with RPS 200 Optional Redundant Power Supply (DGS-3200-24 only) One connector in back to install optional external RPS. When internal power fails, the optional external RPS will take over all the power supply immediately and automatically.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Appendix B – Cables and Connectors When co nnecting t he Switch to ano ther sw itch, a bridge or hub, a normal cable is necessary. Please review t hese products for matching cable pin assignment. The following diagrams and tables show the standard RJ-45 receptacle/connector and their pin assignments. Appendix B- 1.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Appendix C – Module Specs and Cable Lengths Use the following table to as a guide for the module specs and maximum cable lengths.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch Appendix D – Glossary 1000BASE-SX: A short laser wavelength on multimode fiber optic cable for a maximum length of 2 kilometers. 1000BASE-LX: A long wavelength for a "long haul" fiber optic cable for a maximum length of 10 kilometers. 100BASE-FX: 100Mbps Ethernet implementation over fiber. 100BASE-TX: 100Mbps Ethernet implementation over Category 5 and Type 1 Twisted Pair cabling. 10BASE-T: The IEEE 802.
xStack® DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch latency: The delay between the time a device receives a packet and the time the packet is forwarded out of the destination port. line speed: See baud rate. main port: The port in a resilient link that carries data traffic in normal operating conditions. MDI - Mediu m Dependent Interface: An Et hernet port co nnection where t he transmitter o f one d evice is co nnected t o the receiver of another device.
Subject to the terms and conditions set forth herein, D-Link Systems, Inc. (“D-Link”) provides this lifetime product warranty for hardware: Only for products purchased, delivered and used within the fifty states of the United States, the District of Columbia, U.S. Possessions or Protectorates, U.S. Military Installations, or addresses with an APO or FPO, and; Only with proof of purchase.
Limitation of Liability: TO THE MAXIMUM EXTENT PERMITTED BY LAW, D-LINK IS NOT LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOSS OF USE OF THE PRODUCT, INCONVENIENCE OR DAMAGES OF ANY CHARACTER, WHETHER DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF GOODWILL, LOSS OF REVENUE OR PROFIT, WORK STOPPAGE, COMPUTER FAILURE OR MALFUNCTION, FAILURE OF OTHER EQUIPMENT OR COMPUTER PROGRAMS TO WHICH D-LINK’S PRODUCT
Product Registration Register your D-Link product online at http://support.dlink.com/register/ Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights.
Tech Support Technical Support You can find software updates and user documentation on the DLink website. D-Link provides free technical support for customers within the United States and within Canada for the duration of the service period, and warranty confirmation service, during the warranty period on this product. U.S. and Canadian customers can contact D-Link technical support through our website, or by phone.
Technical Support United Kingdom (Mon-Fri) Home Wireless/Broadband 0871 873 3000 (9.00am–06.00pm, Sat 10.00am-02.00pm) Managed, Smart, & Wireless Switches, or Firewalls 0871 873 0909 (09.00am – 05.30pm) (BT 10ppm, other carriers may vary.) Ireland (Mon-Fri) All Products 1890 886 899 (09.00am-06.00pm, Sat 10.00am-02.00pm) €0.05ppm peak, €0.045ppm off peak Times Internet http://www.dlink.co.uk ftp://ftp.dlink.co.uk Technische Unterstützung Deutschland: Österreich: Schweiz: Web: http://www.dlink.
Assistance technique Assistance technique D-Link sur internet :http://www.dlink.fr Assistance technique D-Link par téléphone : 0820 0803 03 0.12 € TTC/min depuis un poste fixe Du lundi au vendredi de 9h à 19h (hors jours fériés) Asistencia Técnica Asistencia Técnica Telefónica de D-Link: +34 902 30 45 45 0,067 €/min De Lunes a Viernes de 9:00 a 19:00 http://www.dlink.es Supporto tecnico Supporto Tecnico dal lunedì al venerdì dalle ore 9.00 alle ore 19.
Pomoc techniczna Telefoniczna pomoc techniczna firmy D-Link: 0 801 022 021 Pomoc techniczna firmy D-Link świadczona przez Internet: http://www.dlink.eu/support/ Technická podpora Web: http://www.dlink.cz/support/ E-mail: support@dlink.cz Telefon ČR: +420 211 151 640 nebo SK: +421 (0)692 147 110 Telefonická podpora je v provozu: PO - PÁ od 09:00 do 17:00 Volání je zpoplatněno dle příslušných tarifů Vašeho operátora. Technikai Támogatás Tel.
Teknistä tukea asiakkaille Suomessa: Internetin kautta : http://www.dlink.fi Arkisin klo. 9 - 21 Numerosta : 0600 155 57 Teknisk Support D-Link Teknisk Support via Internet: http://www.dlink.se D-Link Teknisk Support via telefon: 0900-100 77 00 Vardagar 08:00-20:00 Assistência Técnica Assistência Técnica da D-Link na Internet: http://www.dlink.pt e-mail: soporte@dlink.
Tehnička podrška Hvala vam na odabiru D-Link proizvoda. Za dodatne informacije, podršku i upute za korištenje uređaja, molimo vas da posjetite D-Link internetsku stranicu na www.dlink.eu www.dlink.biz/hr Tehnična podpora Zahvaljujemo se vam, ker ste izbrali D-Link proizvod. Za vse nadaljnje informacije, podporo ter navodila za uporabo prosimo obiščite D-Link - ovo spletno stran www.dlink.eu www.dlink.biz/sl Suport tehnic Vă mulţumim pentru alegerea produselor D-Link.
Technical Support You can find software updates and user do cumentation on the D-Link website. Tech Support for customers in Australia: Tel: 1300-766-868 24/7 Technical Support Web: http://www.dlink.com.au E-mail: support@dlink.com.au India: Tel: +91-22-27626600 Toll Free 1800-22-8998 Web: www.dlink.co.in E-Mail: helpdesk@dlink.co.in Singapore, Thailand, Indonesia, Malaysia, Philippines, Vietnam: Singapore - www.dlink.com.sg Thailand - www.dlink.co.th Indonesia - www.dlink.co.id Malaysia - www.dlink.com.
Technical Support You can find software updates and user documentation on the D-Link website. Tech Support for customers in Iran Unit 5, 5th Floor, No. 20, 17th Alley , Bokharest St. , Argentine Sq. , Tehran IRAN Postal Code : 1513833817 Tel: +98-21-88880918,19 +98-21-88706653,54 General Inquiries: info.ir@dlink-me.com Tech Support: support.ir@dlink-me.com Morocco M.I.T.C Route de Nouaceur angle RS et CT 1029 Bureau N° 312 ET 337 Casablanca , Maroc Phone : +212 663 72 73 24 Email: support.na@dlink-me.
Техническая поддержка Обновления программного обеспечения и документация доступны на Интернет-сайте D-Link. D-Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока. Клиенты могут обратиться в группу технической поддержки D-Link по телефону или через Интернет. Техническая поддержка D-Link: +7(495) 744-00-99 Техническая поддержка через Интернет http://www.dlink.ru e-mail: support@dlink.ru Офисы Украина, 04080 г. Киев , ул. Межигорская, 87-А, офис 18 Тел.
SOPORTE TÉCNICO Usted puede encontrar actualizaciones de softwares o firmwares y documentación para usuarios a través de nuestro sitio www.dlinkla.
Suporte Técnico Caso tenha dúvidas na instalação do produto, entre em contato com o Suporte Técnico D-Link por: Chat Online www.dlink.com.br/suporte E-mail suporte@dlink.com.br Back Office backoffice@dlink.com.br * *Acionar Garantia para 4 ou mais equipamentos Telefones São Paulo: (11) 2755-6950 *GO: 4052-1850 (Ligação local) *Nordeste: 0800-7024104 *Demais Estados: 4062-1850 (Ligação local) *Apenas Modems ADSL Garantia diferenciada vendida pela internet.
D-Link 友訊科技 台灣分公司 技術支援資訊 如果您還有任何本使用手冊無法協助您解決的產品相關問題,台灣 地區用戶可以透過我們的網站、電子郵件或電話等方式與D-Link台灣 地區技術支援工程師聯絡。 D-Link 免付費技術諮詢專線 0800-002-615 服務時間:週一至週五,早上9:00到晚上9:00 (不含周六、日及國定假日) 網 站:http://www.dlink.com.tw 電子郵件:dssqa_service@dlink.com.tw 如果您是台灣地區以外的用戶,請參考D-Link網站全球各地 分公司的聯絡資訊以取得相關支援服務。 產品保固期限、台灣區維修據點查詢,請參考以下網頁說明: http://www.dlink.com.
Dukungan Teknis Update perangkat lunak dan dokumentasi pengguna dapat diperoleh pada situs web D-Link. Dukungan Teknis untuk pelanggan: Dukungan Teknis D-Link melalui telepon: Tel: +62-21-5731610 Dukungan Teknis D-Link melalui Internet: Email : support@dlink.co.id Website : http://support.dlink.co.
Technical Support この度は弊社製品をお買い上げいただき、誠にありがとうご ざいます。 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただき、ダウンロードサービスにて サポート情報、ファームウェア、ユーザマニュアルを ダウンロードすることができます。 ディーリンクジャパン Web サイト URL:http://www.dlink-jp.
技术支持 办公地址:北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02-05 室 邮编: 100013 技术支持中心电话:8008296688/ (028)66052968 技术支持中心传真:(028)85176948 各地维修中心地址请登陆官方网站查询 网址:http://www.dlink.com.
Registration Card All Countries and Regions Excluding USA Print, type or use block letters. Your name: Mr./Ms_____________________________________________________________________________ Organization: ________________________________________________ Dept.