To display the current status of the syslog function:
DGS3048#show syslog
Command: show syslog
Syslog Global State: Enabled
DGS3048#
create syslog host
Purpose Used to create a new syslog host.
Syntax
create syslog host <index 1-4> ipaddress <ipaddr> {severity
[informational | warning | all | facility [local0 | local1| local2 |
local3 | local4 | local5 | local6 | local7] | udp_port
<udp_port_number>
Description
The create syslog host command is used to create a new syslog
host.
Parameters
all − Specifies that the command will be applied to all hosts.
<index 1-4> − Specifies that the command will be applied to an index
of hosts. There are four available indexes, numbered 1 through 4.
ipaddress <ipaddr> − Specifies the IP address of the remote host
where syslog messages will be sent.
severity − Severity level indicator. These are described in the
following:
Bold font indicates that the corresponding severity level is currently
supported on the Switch.
Numerical Severity
Code
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
informational − Specifies that informational messages will be sent to
the remote host. This corresponds to number 6 from the list above.
warning − Specifies that warning messages will be sent to the
remote host. This corresponds to number 4 from the list above.
all − Specifies that all of the currently supported syslog messages
that are generated by the Switch will be sent to the remote host.
facility − Some of the operating system daemons and processes
have been assigned Facility values. Processes and daemons that
have not been explicitly assigned a Facility may use any of the "local
use" facilities or they may use the "user-level" Facility. Those
Facilities that have been designated are shown in the following:
Bold font indicates the facility values that the Switch currently
supports.