Specifications

DGS-3048 Layer 2 Switch CLI Reference Manual
59
To display the current status of the syslog function:
DGS3048#show syslog
Command: show syslog
Syslog Global State: Enabled
DGS3048#
create syslog host
Purpose Used to create a new syslog host.
Syntax
create syslog host <index 1-4> ipaddress <ipaddr> {severity
[informational | warning | all | facility [local0 | local1| local2 |
local3 | local4 | local5 | local6 | local7] | udp_port
<udp_port_number>
Description
The create syslog host command is used to create a new syslog
host.
Parameters
all Specifies that the command will be applied to all hosts.
<index 1-4> Specifies that the command will be applied to an index
of hosts. There are four available indexes, numbered 1 through 4.
ipaddress <ipaddr> Specifies the IP address of the remote host
where syslog messages will be sent.
severity Severity level indicator. These are described in the
following:
Bold font indicates that the corresponding severity level is currently
supported on the Switch.
Numerical Severity
Code
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
informational Specifies that informational messages will be sent to
the remote host. This corresponds to number 6 from the list above.
warning Specifies that warning messages will be sent to the
remote host. This corresponds to number 4 from the list above.
all Specifies that all of the currently supported syslog messages
that are generated by the Switch will be sent to the remote host.
facility Some of the operating system daemons and processes
have been assigned Facility values. Processes and daemons that
have not been explicitly assigned a Facility may use any of the "local
use" facilities or they may use the "user-level" Facility. Those
Facilities that have been designated are shown in the following:
Bold font indicates the facility values that the Switch currently
supports.