Port Bandwidth
The bandwidth control settings are used to place a
ceiling on the transmitting and receiving data rates
for any selected port. In the Configuration folder,
click QoS > Port Bandwidth, to view the
window shown below.
Figure 7- 42. Bandwidth Settings window
The following parameters can be set or are displayed:
Parameter Description
From/To
A consecutive group of ports may be configured starting with the selected port.
Type
Port Bandwidth is only supported for Rx or receiving frames on this Switch.
No Limit
This drop-down menu allows the user to specify that the selected port will have no bandwidth
limit. Enabled disables the limit.
Rate
This field allows the user to select the data rate, in Mbit/s that will be the limit for the selected
port. The user may select one of the following Rx rates: no_limit, 64K, 128K, 256K, 512K, 1M,
2M, 4M, 8M, 16M, 32M, 64M, 128M, 256M, and 512M. If the received rate exceeds the choice
made here, packets are either dropped or subjected to flow control.
Click Apply to set the bandwidth control for the selected ports. Results of configured Bandwidth Settings will be displayed in the
Port Bandwidth Table.
66