Specifications
DGS-3024 Layer 2 Switch CLI Reference Manual
DGS-3024:4#create syslog host 1 ipaddress 10.53.13.94 severity all facility local0
Command: create syslog host 1 ipaddress 10.53.13.94 severity all facility local0
Success.
DGS-3024:4#
config syslog host
Purpose Used to configure the syslog protocol to send system log data to a
remote host.
Syntax
config syslog host {host [all <index 1-4>]} {severity [informational
| warning | all] | facility [local0 | local1 | local2 | local3 | local4 |
local5 | local6 | local7] | udp_port <udp_port_number> | ipaddress
<ipaddr> | state [enable | disable]}
Description
The config syslog host command is used to configure the syslog
protocol to send system log information to a remote host.
Parameters
all − Specifies that the command will be applied to all hosts.
<index 1-4> − Specifies that the command will be applied to an index
of hosts. There are four available indexes, numbered 1 through 4.
severity − Severity level indicator. These are described in the
following:
Bold font indicates that the corresponding severity level is currently
supported on the Switch.
Numerical Severity
Code
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
informational − Specifies that informational messages will be sent to
the remote host. This corresponds to number 6 from the list above.
warning − Specifies that warning messages will be sent to the remote
host. This corresponds to number 4 from the list above.
Parameters
all − Specifies that all of the currently supported syslog messages that
are generated by the Switch will be sent to the remote host.
facility − Some of the operating system daemons and processes have
been assigned Facility values. Processes and daemons that have not
been explicitly assigned a Facility may use any of the "local use"
facilities or they may use the "user-level" Facility. Those Facilities that
have been designated are shown in the following: Bold font indicates
the facility values the Switch currently supports.
Numerical Facility
59