DES-7200 Hardware Installation Guide
DES-7200 Series Hardware Installation Guide Revision No.:V1.6 Date: 2010/7/23 Copyright statement All rights reserved. D-Link Corporation reserves all copyrights o f t his do cument. A ny r eproduction, ex cerption, ba ckup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of D-Link Corporation is prohibited. Exemption statement This document is provided “as i s”.
Preface Thank you for using our switches. This manual provides you with detailed operation guide that allows you to easily install and use the switches. Scope This manual introduces f unctional a nd physical f eatures of our s witches and pr ovides installation procedures, troubleshooting, technical specifications, and rules of using cables and c onnectors.
D-Link C orporation provides ex cellent technical s upport s ervices f or a ll o ur products. You can obtain the technical assistance you need through any of the following channels: Technical Assistance D-Link Corporation Website, On D-Link Corporation Website, you can obtain the latest technical information, reasons of common faults, problem analysis, product application solution and software upgrading information.
Contents 1 Product Overview ................................................................................................................................ 1-1 1.1 1.2 1.3 1.4 1.5 1.6 2 Product Overview.......................................................................................................................1-1 Technical Specifications of DES-7206/7210 ..............................................................................1-2 1.2.1 Product Features .................................
2.5 3 Product Installation.............................................................................................................................. 3-1 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 4 Installation Flow .........................................................................................................................3-2 Installation Verification .............................................................................................
5.1 5.2 General Flow for Troubleshooting Installation Faults.................................................................5-1 Common Troubleshooting Procedures.......................................................................................
DES-7200 Hardware Installation Guide 1 1.1 Product Overview Product Overview In recent years as the Internet users grow at an explosive rate, they are no longer satisfied with various existing ways of communications that rely largely on telephone networks, and demand telecom operators to provide multimedia services such as voice, data, and image.
DES-7200 Hardware Installation Guide 1.2 1.2.1 Technical Specifications of DES-7206/7210 Product Features Powerful expandability DES-7200 supports strategic routing and IPv6. It provides f aster and more effective processing ability by expanding high-performance multi-service cards.
DES-7200 Hardware Installation Guide The PVLAN (port protection) is used to isolate the information exchanged between users, without needing to occupy the VLAN resources. The port MAC address lock and port MAC address access quantity restriction can bar the access from illegal hosts.
DES-7200 Hardware Installation Guide 1.2.2 Technical Specifications Table 1-1 Technical Specifications Product Model DES-7210: DES-7206: Module slot 10 (two for the management engine modules) 6 (two for the management engine modules) VLAN 4K L2 Protocol IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3ae, IEEE802.3x, IEEE802.3ad, IEEE802.3af, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q, IEEEE802.1d, IEEEE802.1w, IEEEE802.
DES-7200 Hardware Installation Guide Product Model DES-7210: DES-7206: Power supply redundancy Supported (must be the same type [all AC or DC]) Fan 7210-FAN (supporting hot swap ability and fault alarming) 7206-FAN (supporting hot swap ability and fault alarming) Environment EMC GB9254-1998 FCC Class A Safety regulation GB4943-2001 MTBF 438,352hrs Operating temperature 0 to 40°C Storage temperature -40 to 70°C Operating humidity 10% - 90% RH 505,339hrs Weight Main unit: 67.
DES-7200 Hardware Installation Guide 1.3 1.3.1 Product Appearance Appearance of the DES-7210 Figure 1-1 Appearance of the DES-7210 (1) (2) (3) (4) (5) (6) 1-6 1. Air outlet layer: the air outlet layer of the entire system, discharging air on three sides; 2. Fan tray: the slot for the fan tray, which is the main heat dissipation unit of the system; 3. Modular p layer: providing 10 v ertical m odule s lots, which h ouse different f unctional modules; 4.
DES-7200 Hardware Installation Guide 1.3.2 Appearance of the DES-7206 Figure 1-2 Appearance of the DES-7206 (3) (1) (2) 1.4 1. Module layer: offering up to 6 module slots; 2. Power layer: supporting two AC or DC power supplies for the maximum. 3. Air outlet: located at the back of the chassis to discharge air. DES-7206/7210 Hardware Composition The DES-7210 hardware system consists of the chassis, power system, system modules, cabling rack, fan tray, air inlet/outlet ducts and air filter.
DES-7200 Hardware Installation Guide The system module layer is a module plug-in frame, which mechanically supports various modules of the DES-7210 system. At the bottom of the chassis are two power frames, above which are the air inlet layer. The air filter is located between the air inlet layer and the cabling rack, which is located below the system module l ayer. A bove t he s ystem module l ayer i s t he f an layer, which houses s ix layers.
DES-7200 Hardware Installation Guide The slots for the two management modules are in the middle, and they are identified as M1 and M2 from left to right. The other eight module line cards are numbered as 1-8 from the left to the right.
DES-7200 Hardware Installation Guide Figure 1-4 Ventilation/Heat Dissipation Solution of the DES-7206 Note 1.6 This structure is designed with air inlet from the front panels of the modules, and air outlet at the back. Six 120*120*38 fans are used to blow the air to the outside for convection and ultimately heat dissipation. Therefore, the chassis should be mounted at a place with adequate spacing around for air circulation.
DES-7200 Hardware Installation Guide 7200-2XG module: I t provides t wo 10-Gigabit XFP i nterfaces. It f eatures t he f unctions of layer-2/3 wire speed switching and routing, and supports multi-mode XFP module with the wavelength being 850nm, single-mode XFP module with that being 1310nm, and single XFP module with that being 1550nm. 7200-4XG module: I t pr ovides f our 10-Gigabit XFP interfaces.
DES-7200 Hardware Installation Guide Note In t he s ystem, t here m ust be at least one 7200 Control Module f or t he system t o w ork nor mally. However, you are r ecommended t o c onfigure this module for both slots for higher reliability. Figure 1-5 Basic Appearance of the 7200-CM1 Figure 1-6 Basic Appearance of the 7200-CM2 Figure 1-7 Basic Appearance of the 7200-CM3 Figure 1-8 Basic Appearance of the 7200-CM4 1.
DES-7200 Hardware Installation Guide Note Note The Firmware v10.0 does not support any USB interface. To use a USB interface, you must adopt the Firmware v10.1 or a later version. To secure data and prevent damage on the device, it is recommended to use qua lified U SB f lash di sk. The U SB interface of DES-7200 is compatible with most USB controllers. Some types of USB flash disk may not be identified. You are recommended to use Patriot and Start-net Digital USB flash disk. 2.
DES-7200 Hardware Installation Guide 1.6.2 Product Model 7200-CM1 7200-CM2 EMC GB9254-1998 FCC Class A Safety regulation GB4943-2001 MTBF 246,987hrs Operating temperature 0 to 40°C Storage temperature -40 to 70°C Operating humidity 10% - 90% RH Weight Net weight: 2.8 Kg Dimensions 436*346×30 ( Lx W x Hmm) 240,558hrs 7200-CM3 7200-CM4 174,420hrs 173,868hrs 7200-24G Module Figure 1-9 shows the basic appearance of the 7200-24G, which is the line card module of the DES-7210/7206.
DES-7200 Hardware Installation Guide Table 1-4 LEDs on the Front Panel Sign Description Detailed Information Status System LED OFF: The module has not been powered on Red: Module fault Flashing green: The module is initializing Solid green: The module has finished initialization and can perform switching normally Link/ACT Port status LED OFF: Port is not linked Green: Port is linked Flashing green: data transmission at the port 3.
DES-7200 Hardware Installation Guide Figure 1-10 Basic Appearance of the 7200-24 1. Interface 7200-24: It provides twelve 10/100/1000BASE-T electrical ports and twelve optical/electrical combo 1000M interfaces, and supports up to twenty-four 1000BASE-T interfaces or 12+M 1000BASE-T interfaces and N 1000BASE-X interfaces, where M plus N equals 12. When the f unction of aut omatic nego tiation is en abled, t he 100 0M el ectrical i nterface s upports automatic MDI/MDI-X identification.
DES-7200 Hardware Installation Guide 1.6.4 Product Model 7200-24 Transmission media 10/100/1000BASE-T: 100m (Category-5 UPT) 1000BASE-SX(850nm) 62.5/125um MMF: 220m 1000BASE-SX(850nm) 50/ 125um M MF: 500m 1000BASE-LX(1310nm) 9/125um S MF: 10KM 1000BASE-LH(1310nm) 9 /125um S MF: 40KM LED Status, Link/ACT Hot swappability Supported Power consumption <85W+15.4xN (N indicates the PoE port being used, of which the value is less than 24.
DES-7200 Hardware Installation Guide 2. LEDs The 7200-48 provides various system LEDs, as described in the following table: Table 1-8 LEDs on the Front Panel Sign Status Link/ACT Description Detailed Information System LED OFF: The module has not been powered on. Red: Module fault Flashing green: The module is initializing. Solid green: The module has finished initialization and can perform switching normally. Port status LED OFF: Port is not linked. Green/Yellow: Port is linked.
DES-7200 Hardware Installation Guide 1.6.5 7200-2XG Module Figure 1-12 shows the basic appearance of the 7200-2XG, which is the line card module of the DES-7200 series. 7200-2XG provides t wo 10-Gigabit XFP interfaces and f eatures the function of layer-2/3 wire speed switching. The 7200-2XG is hot swappable, while supporting hot swappability of the XFP ports. Figure 1-12 Basic Appearance of the 7200-2XG 1.
DES-7200 Hardware Installation Guide 1.6.6 Product Model 7200-2XG MTBF 180,698hrs Operating temperature 0 to 40°C Storage temperature -40 to 70°C Operating humidity 10% - 90% RH Weight Net weight: 2.8 Kg Dimensions 436*346*45 ( L x W x Hmm) 7200-4XG Module Figure 1 -13 shows t he basic app earance of t he 7200-4XG, t he l ine c ard m odule of t he DES-7200 s eries. 7200-4XG provides four 10-Gigabit XFP i nterfaces an d f eatures t he functions of layer-2/3 wire speed switching.
DES-7200 Hardware Installation Guide Table 1-13 Technical Specifications of the 7200-4XG 1.6.7 Product Model 7200-4XG Standard Compliance IEEE 802.3-2002 IEEE 803.ab, IEEE 802.1D, and IEEE 802.1Q 802.1X authentication Port type Four 10-Gigabit XFP interfaces Transmission media 10GBASE-SR(850nm) 62.
DES-7200 Hardware Installation Guide The 7200-24P provides twelve SFP optical ports and 10/100/1000BASE-T ports t hat ar e i n t he c ombo f orm. I n ot her words, eac h SFP por t corresponds t o on e 1 0/100/1000BASE-T por t, and on ly on e port can be used at a time, with the other being unavailable. The MDI/MDI-X automatic identification of the 10/100/1000M electrical ports takes effect only when auto negotiation is enabled. Note 7200-24P does not support the hot pull-out operation.
DES-7200 Hardware Installation Guide 1.6.8 Product Model 7200-24P Transmission media 10/100/1000BASE-T: 100m (Category-5 UPT) 1000BASE-SX(850nm) 62.5/125um M MF: 220m 1000BASE-SX(850nm) 50/125um MMF: 500m 1000BASE-LX(1310nm) 9/125um SMF: 10KM 1000BASE-LH(1310nm) 9 /125um SMF: 40KM LED Status, Link/ACT Hot swappability Supported Power consumption <85W+15.4xN (N indicates the PoE port being used, of which the value is less than 24.
DES-7200 Hardware Installation Guide 7200-48P does not support the hot pull-out operation. You need to perform the following operations to achieve it: 1. Disconnect all cables connected to the cable card ports; 2. Hold the Mode button for over three seconds until all LEDs on the cable card ports go off; 3. Configure the pull-out operation through software commands. (For relevant software configuration commands, refer to the corresponding software description.) Warning 2.
DES-7200 Hardware Installation Guide 1.6.9 Product Model 7200-48P Transmission media 10/100/1000BASE-T: 100m (Category-5 UPT) 1000BASE-SX(850nm) 62.5/125um M MF: 220m 1000BASE-SX(850nm) 50/125um MMF: 500m 1000BASE-LX(1310nm) 9/125um SMF: 10KM 1000BASE-LH(1310nm) 9 /125um SMF: 40KM LED Status, Link/ACT Hot swappability Supported Power consumption <100W+15.4xN (N indicates the PoE port being used, of which the value is less than 48.
DES-7200 Hardware Installation Guide Sign Link/ACT Description Detailed Information Port status LED OFF: Port is not linked. Green: The 1000BASE-X Port is linked. Flashing green: Data is transmitted on the 1000BASE-X port. Orange: The100BASE-X port is linked. Flashing orange: Data is transmitted on the 100BASE-X port. 3. Technical Specifications Table 1-19 Technical Specifications of the 7200-24GE 1.6.10 Product Model 7200-24GE Standard Compliance IEEE 802.3-2002 IEEE 803.ab, IEEE 802.
DES-7200 Hardware Installation Guide 1. Interface 7200-24G2XG comes with two 10G XFP ports, 12 gigabit SFP ports and 12 gigabit optical-electrical multiplex ports, and offers gigabit-level line rate of Layer 2/3 switching. With auto-negotiation enabled, the gigabit electrical port supports automatic MDI/MDI-X identification. The gigabit SFP optical module of short wave (850nm, multi mode), long wave (1310nm, single mode) and long distance (1550nm) is supported on the SFP port.
DES-7200 Hardware Installation Guide 1.6.11 Product Model 7200-24G2XG Hot swappability Supported Power consumption <75W EMC GB9254-1998 FCC Class A Safety regulation GB4943-2001 MTBF 151,800hrs Operating temperature 0 to 40°C Storage temperature -40 to 70°C Operating humidity 10% to 90% RH Weight Net weight: 2.8 Kg Dimensions 436*346*45mm ( L x W x H) 7200-ASE3 Module Figure 1-19 shows the basic appearance of 7200-ASE3. The 7200-ASE3 is an agent card that s upports MPLS.
DES-7200 Hardware Installation Guide 1.6.12 Product Model 7200-ASE3 EMC GB9254-1998 FCC Class A Safety regulation GB4943-2001 MTBF 172,738hrs Operating temperature 0 to 40°C Storage temperature -40 to 70°C Operating humidity 10% to 90% RH Weight Net weight: 2.8 Kg Dimensions 436*346*45mm ( L x W x H) 7206/7210-Fan Module The 7210-Fan is t he f an module of t he DES-7210, while t he 7206-Fan i s t hat o f t he DES-7206.
DES-7200 Hardware Installation Guide 1.6.14 7200-1200DC/2000DC Power Module As the D C po wer m odule of t he s ystem, t he 7200-1200DC/2000DC provides t he i nput interface of -48V DC power supply for the DES-7210/7206. Note Warning 1-30 The DES-7210/7206 system supports 1+1 redundancy for the DC power supply 7200-1200DC/2000DC. F or h igher s tability a nd r eliability of t he entire system, you are recommended to configure 1+1 redundancy of the 7200-1200DC/2000DC for the DES-7210/7206.
DES-7200 Hardware Installation Guide 2 2.1 Preparation Before Installation Safety Suggestions To av oid personal i njury an d equipment d amage, p lease c arefully read t he s afety suggestions before you install the DES-7210/7206. The following safety suggestions do not cover all possible dangers. Note 2.1.1 2.1.2 Safety Precautions for Installing the System Keep the chassis clean, free from any dust. Do not place the equipment in a walking area.
DES-7200 Hardware Installation Guide Figure 2-1 Schematic Diagram for Correctly Moving the DES-7210 Figure 2-2 Schematic Diagram for Correctly Moving the DES-7206 Warning 2.1.3 2-2 Do not move the equipment by grasping the panel, power supply handle, ventilation h oles of t he c hassis, as t hey are not d esigned t o bear t he weight of t he e ntire eq uipment. F ailing to d o s o m ay cause dam age or even injure yourself.
DES-7200 Hardware Installation Guide Do not maintain the equipment alone when it is energized, unless absolutely necessary. Be sure to make a careful check before you shut down the power supply. Do not pl ace t he e quipment i n a d amp/wet location. D o no t l et an y liquid e nter t he chassis Connect the negative and positive lines correctly according to the instructions when DC power supply is used.
DES-7200 Hardware Installation Guide 2.1.5 Laser Safety Among the modules supported by the DES-7210/7206, there are a great number of optical modules that are Class I laser products. Therefore, pay attention to the following during your use of this product: When a fiber transceiver works, ensure that the port has been connected with an optical fiber or is covered with a dust cap, to keep out dust and avoid burning your eyes. Do not stare into any optical port. Danger 2.
DES-7200 Hardware Installation Guide Figure 2-3 Schematic Diagram for the Ventilation of the DES-7210 Figure 2-4 Schematic Diagram for the Ventilation of the DES-7206 2-5
DES-7200 Hardware Installation Guide 2.2.3 Temperature and Humidity Requirements To ensure the normal working and a prolonged useful life of the DES-7210/7206, appropriate temperature and humidity must be maintained in the equipment room. If the equipment room has temperature and humidity that do not meet the requirements for a long time, the equipment may be damaged.
DES-7200 Hardware Installation Guide Apart from dust, the salt, acid and sulfide in the air in the equipment room must also meet strict r equirements, as s uch poi sonous s ubstances may accelerate t he c orrosion of t he metal and t he aging of s ome p arts. T he equ ipment room s hould be pr otected f rom t he intrusion of harmful gases (for example, sulfur dioxide, sulfured hydrogen, nitrogen dioxide, and chlorine), whose requirements are listed in Table 2-3.
DES-7200 Hardware Installation Guide 2.3.3 EMC Ground The gr ound r equired f or E MC des ign i ncludes s hielding gr ound, f ilter gr ound, noise a nd interference suppression, and level reference. All the above constitute the comprehensive grounding r equirements. T he gr ounding r esistance s hould be less t han 1. T he DES-7210/7206 chassis is installed with two grounding posts, as shown in Figure 2-5. Post 1 is i nstalled f or s hell protection a nd p ost 2 i s installed f or c ircuit working.
DES-7200 Hardware Installation Guide 2.3.5 3. Keep the equipment away from high-power radio transmitter, radar transmitting station, and high-frequency large-current device. 4. Measures must be taken to isolate static electricity. Precaution for Fiber Connection Before you connect the fibers, verify that the optical connector type and fiber type match the optical interface type used, and pay attention to the Tx and Rx directions of the fiber.
DES-7200 Hardware Installation Guide 3 Product Installation 1. Note 2. Before you install the DES-7210/7206, make sure you have carefully read Chapter 2 and this chapter. Make sure that the requirements set forth in Chapter 2 have been met.
DES-7200 Hardware Installation Guide 3.
DES-7200 Hardware Installation Guide 3.2 Installation Verification The DES-7210/7206 is a kind of c omplicated eq uipment, s o you m ust c arefully plan a nd arrange its i nstallation location, ne tworking m ode, po wer s upply, and wiring b efore installation. Verify the following before installation: 3.3 3.3.1 The installation location offers sufficient flow of air. The installation location meets the requirements of the equipment for temperature and humidity.
DES-7200 Hardware Installation Guide 4. 3.4 3.4.1 Install the tray and wiring layer on the rack according to the configuration of one rack with one cabinet and one rack with multiple cabinets. Mounting the DES-7210/7206 into the Cabinet Precautions Before the DES-7210/7206 is mounted into the cabinet, first verify that the front and back brackets of the cabinet are at the right locations.
DES-7200 Hardware Installation Guide Figure 3-1 Installing the Fan Tray of the DES-7210 Figure 3-2 Installing the Fan Tray of the DES-7206 3.6 Installing the Power Supply The DES-7210/7206 system provides AC and DC power, which can be installed in the same way by performing the following steps: 1. Remove any blank panel of the power module by loosening the two cross screws with a cross screwdriver, as shown in Figure 3-4 and 3-5.
DES-7200 Hardware Installation Guide Figure 3-3 Schematic Diagram for Installing the Power Supply of the DES-7210 Figure 3-4 Schematic Diagram for Installing the Power Supply of the DES-7206 3-6
DES-7200 Hardware Installation Guide 2.
DES-7200 Hardware Installation Guide 3. Tighten the screws on both sides of the power supply by using a straight screwdriver, as shown in Figure 3-8 and Figure 3-9.
DES-7200 Hardware Installation Guide 3.7 Installing the Handle For eas y handling of t he s ystem, t he DES-7210/7206 chassis i s pr ovided w ith a handle, which can be installed by performing the following steps: 1. Align the handle with the sunk hole on the fastening bar; 2. Tighten the cross M4 sunk screws provided with the unit, as shown in Figure 3-10 and Figure 3-11.
DES-7200 Hardware Installation Guide 3.8 Installing the Cabling Rack of the DES-7210 The cabling rack of the DES-7210 can be performed by performing the following steps: 1. Remove the blank panel of the tracing rack by loosing the captive screws with a straight screwdriver and the cross screws with a cross screwdriver, as shown in Figure 3-12. Figure 3-11 Installing the Cabling Rack of the DES-7210 2.
DES-7200 Hardware Installation Guide Figure 3-12 Installing the Cabling Rack of the DES-7210 3. Fasten t he c abling r ack b y using t he c ross M 3 s crews pr ovided, as s hown in Figure 3-14.
DES-7200 Hardware Installation Guide 3.9 Installing the Air Filter of the DES-7210 Simply push the air filter of the DES-7210 into the cabinet along the guide rail, as shown in Figure 3-15. Figure 3-14 Installing the Air Filter of the DES-7210 Note You are recommended to install the air filter as the last step of the chassis installation. 3.10 Connecting the System Ground A working ground GND is installed on the back of DES-7210/7206.
DES-7200 Hardware Installation Guide Figure 3-15 Connection of grounding posts on the DES-7210/7206 back 3.10.2 3.10.3 Precautions The s ectional area of t he gr ounding c able s hould be det ermined ac cording t o t he possible maximum current. Cables of good conductor should be used. Do not use bare wire. The grounding resistance for combined grounding should be less than 1Ω. Simple Grounding Steps 1. Release the nut on the rear grounding post of the equipment. 2.
DES-7200 Hardware Installation Guide Figure 3-16 Schematic Diagram for the Connection of the DC Power Cable 3.11.2 3.11.3 Precautions Before c onnecting t he p ower s upply, you m ust v erify that the external p ower s upply provided matches the power module installed of this equipment. Before connecting the power cable, you must make sure that the switch of the power module is at the OFF position. The power cables of various colors must be connected to the appropriate wiring posts.
DES-7200 Hardware Installation Guide Figure 3-17 Schematic Diagram for the Connection of the AC Power Cable 3.12.2 3.12.3 Precautions Before c onnecting t he p ower s upply, you m ust v erify t hat the external p ower s upply provided matches the power module installed of this equipment. Before connecting the power cable, you must make sure that the switch of the power module is at the OFF position. The power cable with a standard 3-pin connector should be used for connection.
DES-7200 Hardware Installation Guide 3.14 Removing Boards from the DES-7210/7206 3.14.1 Steps for Removing Boards 1. Unplug all cables/fibers such as optical fibers and RJ45 twisted pairs from the panel. 2. Tighten two captive screws on the panel. 3. Draw out the board by holding the ejector with both hands, as shown in Figure 3-18 and Figure 3-20. 1. Warning 2. Always wear an anti-static wrist strap before plugging/unplugging a board.
DES-7200 Hardware Installation Guide Figure 3-19 Schematic Diagram for the Components of the DES-7206 3.15 Installing Boards on the DES-7210/7206 3.15.1 Simple Steps of Board Installation 1. Remove the appropriate component card or blank panel according to 3.14. 2. Replace it with the appropriate card and insert into the guide rail. 3. Push the card into position by using the ejector, and tighten the two captive screws on the card with a straight screwdriver. 1. Warning 2.
DES-7200 Hardware Installation Guide 3. Insert the twisted pair with the RJ45 port into the appropriate interface according to the identification on the panel of the line card. Distinguish the crossover cable and straight-through cable. 4. Connect the cables and optical fibers of each board in sequence. 3.17 Binding the Cables 3.17.1 3.17.2 Precautions The power cables and other cables should be bound in a visually pleasing way.
DES-7200 Hardware Installation Guide 4 4.1 DES-7210/7206 Maintenance Monitoring Function of the DES-7210/7206 When the DES-7210/7206 is running, you can monitor the status of each board by inspecting the status LED of the appropriate board. When the Status LED of a board is OFF, RED, or flashing, it means that the board is faulty, in which case you need to find out the cause, and s hut do wn t he po wer when n ecessary.
DES-7200 Hardware Installation Guide During the process, you should clean the air filter of the DES-7210/7206. Note 4.2.3 Power Supply Maintenance When the power supply fails, you only need to disconnect the power cable, loosen the two panel screws on the power module, unplug the power module, replace it with a good one, and tighten the panel screws, and then connect the power cables. 4.3 Remote Maintenance The DES-7210/7206 supports remote m aintenance.
DES-7200 Hardware Installation Guide 5 5.
DES-7200 Hardware Installation Guide 5.2 Common Troubleshooting Procedures Fault 1: The system login password is lost. [Fault Description] The s ystem l ogin password of t he s witch is f orgotten or l ost, a nd s o it i s no t possible t o configure the data. [Troubleshooting] Please contact D-Link Customer Service Department for technical support. Fault 2: The AC power module does not work.
DES-7200 Hardware Installation Guide Fault 5: The LED is abnormal after a line card works for some time. [Fault Description] The Status LED of the line card is OFF or RED. The Link/ACT LED of the line card is solid ON when no network cable or optical fiber is plugged. The fault remains after restart. [Troubleshooting] Check if the board gets loose. If yes, install the line card again and ensure that it is inserted into pos ition, before you tighten t he f astening screws.
DES-7200 Hardware Installation Guide The serial port console outputs illegible characters. [Troubleshooting] Such problem i s r elated to t he s ettings of t he s erial p ort. C heck i f t he s ettings of s uch parameters as the baud rate match those in the DES-7210/7206 Configuration Guide.
DES-7200 Hardware Installation Guide A A.1 Appendix Connectors and Connection Media 1000BASE-T/100BASE-TX/10BA SE-T Port The 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and us es t he c able of 100-ohm C ategory-5 or Supper C ategory-5 U TP or STP, which c an b e up to 10 0 m .
Appendix DES-7200 Hardware Installation Guide Figure A-3 Connections of the Twisted Pairs of the 100BASE-TX/10BASE-T A.2 Optical Fiber Connection For the optical fiber ports, select single-mode or multiple-mode optical fibers for connection according t o t he f iber m odule c onnected.
DES-7200 Hardware Installation Guide B Appendix Mini-GBIC and 10G XENPAK Modules We pr ovide the ap propriate 10 00M S FP m odule ( Mini-GBIC m odule) a nd 10G X ENPAK module for the types of interfaces of the switch modules. You can select the SFP or XENPAK module to suit your specific needs. Below the models and technical specifications of some 1000M SFP and 10G XENPAK modules are listed for your reference. B.
B.4 Models and Technical Specifications of the 10G XENPAK Module Table B-2 Models and Technical Specifications of the 10G XENPAK Module XENPAK Model Wavelength Media Type (nm) Core Size (nm) Optical Modular Transmission Intensity Bandwidth Distance (MHz/km) (MAX) 62.5 200 160 Max: 33 m Max: 22 m 50 2000 500 400 Max: 300 m Max: 82 m Max: 66 m -1.0 dBm -11.98 dBm Max. 10KM; 0.5dBm -12.
DES-7200 Hardware Installation Guide XENPAK Model Wavelength (nm) Media Type Appendix Optical Core Modular Transmission Intensity Size Bandwidth Distance (nm) (MHz/km) (MAX) Reception Standard sensitivity Compliance (MAX) 10GBASE1310 LR Single-mode optical fiber 10 (LC connector) N/A Max. 10KM; 0.5dBm -12.6dBm 10GBASE1550 ER Single-mode optical fiber 10 (LC connector) N/A Max. 40KM; 4dBm -13.
Subject to the terms and conditions set forth herein, D-Link Systems, Inc. (“D-Link”) provides this Limited Warranty: • • Only to the person or entity that originally purchased the product from D-Link or its authorized reseller or distributor, and Only for products purchased and delivered within the fifty states of the United States, the District of Columbia, U.S. Possessions or Protectorates, U.S. Military Installations, or addresses with an APO or FPO.
Limitation of Liability: TO THE MAXIMUM EXTENT PERMITTED BY LAW, D-LINK IS NOT LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY LOSS OF USE OF THE PRODUCT, INCONVENIENCE OR DAMAGES OF ANY CHARACTER, WHETHER DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF GOODWILL, LOSS OF REVENUE OR PROFIT, WORK STOPPAGE, COMPUTER FAILURE OR MALFUNCTION, FAILURE OF OTHER EQUIPMENT OR COMPUTER PROGRAMS TO WHICH D-LINK’S PRODUCT
Product Registration Register your D-Link product online at http://support.dlink.com/register/ Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights.
Tech Support Technical Support You can find software updates and user documentation on the DLink website. D-Link provides free technical support for customers within the United States and within Canada for the duration of the service period, and warranty confirmation service, during the warranty period on this product. U.S. and Canadian customers can contact D-Link technical support through our website, or by phone.
Technical Support United Kingdom (Mon-Fri) Home Wireless/Broadband 0871 873 3000 (9.00am–06.00pm, Sat 10.00am-02.00pm) Managed, Smart, & Wireless Switches, or Firewalls 0871 873 0909 (09.00am – 05.30pm) (BT 10ppm, other carriers may vary.) Ireland (Mon-Fri) All Products 1890 886 899 (09.00am-06.00pm, Sat 10.00am-02.00pm) €0.05ppm peak, €0.045ppm off peak Times Internet http://www.dlink.co.uk ftp://ftp.dlink.co.uk Technische Unterstützung Deutschland: Österreich: Schweiz: Web: http://www.dlink.
Assistance technique Assistance technique D-Link sur internet :http://www.dlink.fr Assistance technique D-Link par téléphone : 0820 0803 03 0.12 € TTC/min depuis un poste fixe Du lundi au vendredi de 9h à 19h (hors jours fériés) Asistencia Técnica Asistencia Técnica Telefónica de D-Link: +34 902 30 45 45 0,067 €/min De Lunes a Viernes de 9:00 a 19:00 http://www.dlink.es Supporto tecnico Supporto Tecnico dal lunedì al venerdì dalle ore 9.00 alle ore 19.
Pomoc techniczna Telefoniczna pomoc techniczna firmy D-Link: 0 801 022 021 Pomoc techniczna firmy D-Link świadczona przez Internet: http://www.dlink.eu/support/ Technická podpora Web: http://www.dlink.cz/support/ E-mail: support@dlink.cz Telefon: 225 281 553 Telefonická podpora je v provozu: PO- PÁ od 08.00 do 17.00 Pevná linka 1,78 CZK/min - mobil 5.40 CZK/min Technikai Támogatás Tel. : 06 1 461-3001 Fax : 06 1 461-3004 Land Line 14,99 HUG/min - Mobile 49.99,HUF/min email : support@dlink.
Teknistä tukea asiakkaille Suomessa: Arkisin klo. 9 - 21 numerosta : 06001 5557 Internetin kautta : http://www.dlink.fi Teknisk Support D-Link Teknisk Support via telefon: 0900-100 77 00 Vardagar 08.00-20.00 D-Link Teknisk Support via Internet: http://www.dlink.se Assistência Técnica Assistência Técnica da D-Link na Internet: http://www.dlink.pt e-mail: soporte@dlink.
Tehnička podrška Hvala vam na odabiru D-Link proizvoda. Za dodatne informacije, podršku i upute za korištenje uređaja, molimo vas da posjetite D-Link internetsku stranicu na www.dlink.eu www.dlink.biz/hr Tehnična podpora Zahvaljujemo se vam, ker ste izbrali D-Link proizvod. Za vse nadaljnje informacije, podporo ter navodila za uporabo prosimo obiščite D-Link - ovo spletno stran www.dlink.eu www.dlink.biz/sl Suport tehnic Vă mulţumim pentru alegerea produselor D-Link.
Technical Support You can find software updates and user documentation on the D-Link website. Tech Support for customers in Australia: Tel: 1300-766-868 24/7 Technical Support Web: http://www.dlink.com.au E-mail: support@dlink.com.au India: Tel: 1800-233-0000 (MTNL & BSNL Toll Free) +91-832-2885700 (GSM, CDMA & Others) Web: www.dlink.co.in E-Mail: helpdesk@dlink.co.
Technical Support You can find software updates and user documentation on the D-Link website. Tech Support for customers in Egypt: Tel: +202-2919035, +202-2919047 Sunday to Thursday 9:00am to 5:00pm Web: http://support.dlink-me.com E-mail: support.eg@dlink-me.com Iran: Tel: +98-21-88880918,19 Saturday to Thursday 9:00am to 5:00pm Web: http://support.dlink-me.com E-mail: support.ir@dlink-me.com support@dlink.
Техническая поддержка Обновления программного обеспечения и документация доступны на Интернет-сайте D-Link. D-Link предоставляет бесплатную поддержку для клиентов в течение гарантийного срока. Клиенты могут обратиться в группу технической поддержки D-Link по телефону или через Интернет. Техническая поддержка D-Link: +7(495) 744-00-99 Техническая поддержка через Интернет http://www.dlink.ru e-mail: support@dlink.
SOPORTE TÉCNICO Usted puede encontrar actualizaciones de softwares o firmwares y documentación para usuarios a través de nuestro sitio www.dlinkla.
Suporte Técnico Você pode encontrar atualizações de software e documentação de usuário no site da D-Link Brasil. A D-Link fornece suporte técnico gratuito para clientes no Brasil durante o período de vigência da garantia deste produto. Suporte Técnico para clientes no Brasil: Website para suporte: www.dlink.com.br/suporte e-mail: suporte@dlink.com.
D-Link 友訊科技 台灣分公司 技術支援資訊 如果您還有任何本使用手冊無法協助您解決的產品相關問題,台灣 地區用戶可以透過我們的網站、電子郵件或電話等方式與D-Link台灣 地區技術支援工程師聯絡。 D-Link 免付費技術諮詢專線 0800-002-615 服務時間:週一至週五,早上9:00到晚上9:00 (不含周六、日及國定假日) 網 站:http://www.dlink.com.tw 電子郵件:dssqa_service@dlink.com.tw 如果您是台灣地區以外的用戶,請參考D-Link網站全球各地 分公司的聯絡資訊以取得相關支援服務。 產品保固期限、台灣區維修據點查詢,請參考以下網頁說明: http://www.dlink.com.
Dukungan Teknis Update perangkat lunak dan dokumentasi pengguna dapat diperoleh pada situs web D-Link. Dukungan Teknis untuk pelanggan: Dukungan Teknis D-Link melalui telepon: Tel: +62-21-5731610 Dukungan Teknis D-Link melalui Internet: Email : support@dlink.co.id Website : http://support.dlink.co.
Technical Support この度は弊社製品をお買い上げいただき、誠にありがとうご ざいます。 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただくと、ダウンロードサービスにて サポート情報、ファームウェア、ユーザマニュアルを ダウンロードすることができます。 ディーリンクジャパン Web サイト URL:http://www.dlink-jp.
技术支持 办公地址:北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02-05 室 邮编: 100013 技术支持中心电话:8008296688/ (028)66052968 技术支持中心传真:(028)85176948 各地维修中心地址请登陆官方网站查询 网址:http://www.dlink.com.
Registration Card All Countries and Regions Excluding USA Print, type or use block letters. Your name: Mr./Ms_____________________________________________________________________________ Organization: ________________________________________________ Dept.