User manual
xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch
14
Figure 2 - 9. The DES-3828 with the DPS-200 chassis RPS
1. Insert one end of the 14-pin DC power cable into the receptacle on the switch and the other end
into the redundant power supply.
2. Using a standard AC power cable, connect the redundant power supply to the main AC power
source. A green LED on the front of the DPS-200 will glow to indicate a successful connection.
3. Re-connect the switch to the AC power source. On certain switches, such as the DES-3828, an
LED indicator will show that a redundant power supply is now in operation.
4. No change in switch configuration is necessary for this installation.
NOTE: See the DPS-200 documentation for more information.
CAUTION: Do not use the Switch with any redundant power system other than
the DPS-200 or DPS 600.
DPS-600
DES-3828P also supports the DPS-600 external redundant power supply.