Specifications

Access Control
LNL-1100 Series 2
The Lenel Input Control Module (ICM) provides the access control system with high-speed
acknowledgment of critical alarm points in monitored areas. The ICM communicates directly with
the Intelligent System Controller (ISC) either by 2-wire or 4-wire RS-485 communication. The ICM
has 16 configurable input control points and 2 output control relays. It supports normally open,
normally closed, supervised and non-supervised circuits.
The input circuits are scanned using an analog-to-digital converter. The digitized input status
signal is software-monitored and controlled, so that each input point can be programmed as a
supervised or non-supervised alarm point.
The output relays can also be configured for fail-safe or fail-secure operation. Each relay supports
the “On,” “Off,” and “Pulse” Lenel OnGuard software commands.
Features and Functionality
Grade B, A, and AA line supervision
12 or 24 VDC input power
16 programmable supervised or non-supervised contacts
2 Form-C 5 A, 30 VDC contacts for load switching
2 dedicated inputs for tamper and power failure status
On-board termination jumpers
DIP switch-selectable addressing
Elevator control, support for 64 floors
Status LED for host communication and heartbeat
Variable resistor values for line supervision
Downloadable firmware
Input Control Module
15