User manual
D-Link Web Smart Switch User Manual
Flo
w Control: You can enable this function to mitigate the traffic congestion. Ports configured for full-duplex
use 802.3x flow control, half-duplex ports use backpressure flow control. The default setting is disabled.
DES-1100-26
Figure 41 – System > Port Setting
Speed: Copper connections of Port1, Port2, … , Port25, and Port26 can operate in Forced Mode settings
(100M Full, 100M Half, 10M Full, 10M Half), Auto, or Disabled. Fiber connection of Port25 and Port26 can
only operate in Forced Mode setting 1000M Full and Auto, but can not be disabled. The default setting for all
ports is Auto.
NOTE: Be sure to adjust port speed settings
appropriately after changing connected cable
media types.
Link Status: Reporting Down indicates the port is disconnected.
Flow Control: You can enable this function to mitigate the traffic congestion. Ports configured for full-duplex
use 802.3x flow control, half-duplex ports use backpressure flow control. The default setting is disabled.
System > Trap Settings For SmartConsole
By configuring the Trap Setting, it allows SmartConsole Utility to monitor specified events on this EasySmart
Switch. By default, Trap Setting is disabled. When the Trap Setting is enabled, enter the Destination IP
address of the managing station that will receive trap information.