Specifications
B-102
Storage Area Network (SAN) Arrays
Model DSN-1100-10 DSN-2100-10 DSN-3200-10 DSN-3400-10
Storage
Feature
DriveBay 5 8 15
Drive Interface Support SATA-II
System Memory
256MBto512MB
(256MBStandard)
256MBto512MB
(512MBStandard)
CacheMemory
256MBto1GB
(256MBStandard)
256MBto4GB
(512MBStandard)
BatteryBackupforCache Standard(Approximately72hoursonFullCharge)
Bandwidth Upto425MB/s Upto850MB/s Upto1160MB/s
StorageCapacity
1
5TBwith1TBHDDs 8TBwith1TBHDDs 15TBwith1TBHDDs
SupportedNICs,ISCI
AcceleratorsandiSCSIHBAs
2
Intel
®
Pro1000MT&XT(1GbE)
Alacritech
®
SES2104ET(SNP9.1.0.1092&7.3.1.0)
Alacritech
®
SES2102ET(SNP9.1.0.1092&7.3.1.0)
Qlogic
®
4010C,4052C&4062C
Intel
®
Pro1000MT&XT(1GbE)
Intel
®
Pro1000CX4(1GbE)
Myricom10G-PCIE-8A-C+E(10GbE)
Chelsio
®
S310X-SR-XFP(10GbE)
Neterion
®
Xframe®II&Xframe
®
E (10GbE)
Alacritech
®
SES2104ET(SNP9.1.0.1092&7.3.1.0)
Alacritech
®
SES2102ET(SNP9.1.0.1092&7.3.1.0)
Qlogic
®
4010C,4052C&4062C
Supported Operating Systems
2
WindowsVista
®
32-bit&x64(Ultimate&Enterprise)withBuilt-iniSCSIInitiator
WindowsServer2003
®
32-bit&x64SP1(Standard&Enterprise)withv2.07iSCSIInitiator
WindowsServer2003
®
R232-bit&x64SP1(Standard&Enterprise)withv2.07iSCSIInitiator
WindowsXPPro
®
32-bit&x64withv2.07iSCSIInitiator
Windows2000AdvancedServer
®
withv1.6&v2.01iSCSIInitiator
Red Hat
®
7.3; Red Hat
®
EnterpriseASUpdate5
SuSE
®
EnterpriseServer10.232-bit(x86);SuSE
®
Professional9.332-bit&x64
MacOSX(10.4&10.5)
iSCSINetwork
Interface
iSCSINetworkInterface Four1GbECopperPorts Eight1GbECopperPorts
One10GbEXFP
(XFPsoldseparately)
Host Interface iSCSIDraft20CompliantInitiator
Connections 1,024Hosts
CHAPAuthentication Yes
AccessControlofManagement Yes
iSCSI/TCP/IPFullHardware
Offload
Yes
JumboFrame Yes
IEEE802.3adLinkAggregation UptoFourLAGs UptoEightLAGs Not Applicable
IEEE802.1QVirtualLAN(VLAN)
UptoFour1-to-1
Mapping between IP
SubnetandVLAN
UptoEight1-to-1MappingbetweenIPSubnetandVLAN
Volume&RAID
RAIDController Single-IntegratedinASIC
RAID Support RAID Levels 0, 1, 1+0 and 5
Volumes 1,024VirtualVolumes(256AccessibleperInitiator)
Target Nodes 1,024
OnlineCapacityExpansion Yes
Hot-Swappable Drives Yes
InstantVolumeAccess Yes
Free Space Defragmentation Yes
Auto-Detection Failed Drive Yes
Auto-Rebuild Spare Drive Yes
RAID Level Migration Yes
Drive Roaming in Power Off Yes(ConguredDrivesareNotBay-Specic)
Micro Rebuilds Yes
Storage
Management
Embedded IP-based
ManagementGUI
Create,Mange,ExpandandMonitorStoragePool,VolumesandRAID
FirmwareFieldUpgradable Yes
Power
Supply Type 1U200-Watt Redundant2U400-Watt Redundant3U2+1760-Watt
InputVoltage 100~240VAC 90~264VAC(Auto-Switching)
Input Frequency 50~60Hz 47~63Hz
InputCurrent(Maximum) 4A 8A@100VAC;4A@240VAC 20A@90VAC;10A@264VAC
PowerFactorCorrection 95%@110V,FullLoad
PowerConsumption(Full
Conguration)
112-Watt 360-Watt 570-Watt
Thermal(FullConguration) 815BTU/hour 1,260BTU/hour 2,000BTU/hour
Environmental
Operating Temperature 0°Ct040°C
Storage Temperature -20°Ct070°C
Operating Humidity 20%to90%(Non-Condensing)
Storage Humidity 10%to95%(Non-Condensing)
Physical
Form Factor Tower 2U,19-inchRack-Mount 3U,19-inchRack-Mount
Dimension(WxDxH) 167x273x259mm 438x635x89mm 438x571x133mm
Weight(FullConguration) 4.0 kg 20.4kg 33 kg
Certication
Emission FCCClassA;CEClassA;C-TickClassA;VCCIClassA
Safety CSA60950-1;UL60950-1;IEC60950-1;EN60950-1
1
Support for higher capacity drives as they are introduced
2
Please refer to D-Link website for latest support information
Storage Area Network (SAN) ArraysNETWORK STORAGE
B-106