Systems Network Router User Manual

D-Link Product Guide 2008
26
LAN SWITCHES
Features & Benefits
D-Link Product Guide 2008
27

These redundant power supplies (RPS) connect to the D-Link Ethernet or Gigabit
switches to provide backup power for the built-in power supply units inside the
switches. The redundant power supplies can be installed as stand-alone power
supply units, or mounted in a DPS-900 or DPS-800 chassis. The chassis has
multiple slots that can accommodate several redundant power supply units, and
can be mounted in a standard 19-inch equipment rack. All RPS units have solid
metal case housing and LED status indicators. As they are independent units, they
are hot swappable when used with the chassis.

8 Slots Accommodating 8 RPS Units
19-Inch Width for Mounting in Standard
Equipment Racks

Power Cable
8-Slot Chassis
Power Cable for DPS-200, DPS-300 &
DPS-500 RPS
● 4 Meters Cable Length













AC Redundant Power Supply

Maximum 140 Watts’ Output Power
Over Current Protection
Can be mounted in DPS-800 or DPS-
900 Chassis
DC Redundant Power Supply
Maximum 500 Watts’ Output Power
90 to 264 Volts, 47 to 63Hz AC Input
Range
Over Current Protection
19-Inch Width for Mounting in Standard
Equipment Racks

AC Redundant Power Supply

Maximum 60 Watts’ Output Power
90 to 264 Volts, 47 to 63Hz AC Input
Range
● Over Current Protection
Can be mounted in DPS-800 or DPS-
900 Chassis
AC Redundant Power Supply
Maximum 90 Watts’ Output Power
90 to 264 Volts, 47 to 63Hz AC Input
Range
Over Current Protection
Can be mounted in DPS-800 or DPS-
900 Chassis

2-Slot Chassis
2 Slots Accommodating 2 RPS Units
19-Inch Width for Mounting in
Standard Equipment Racks

AC Redundant Power Supply
Maximum 140 Watts’ Output Power
90 to 264 Volts, 47 to 63Hz AC Input
Range
● Over Current Protection
Can be mounted in DPS-800 or DPS-
900 Chassis
Redundant Power Supply & LAN Switch Compatibility
RPS
DPS-200 (60 Watts) DPS-300 (90 Watts) DPS-500 (140 Watts) DPS-600 (500 Watts)
Switch
DES-3326SR
DES-3350SR
DES-3400-28
DES-3400-28P
DES-3400-52
DES-3400-52P
DES-3526
DES-3550
DES-3700-28M
DES-3828
DES-3828P
DES-3852
DGS-3024
DGS-3048
DGS-3100-24
DGS-3100-48
DGS-3100-24P
DES-3700-28
DGS-3100-48P
DGS-3224TGR
DGS-3312SR
DGS-3426
DGS-3427
DGS-3450
DGS-3324SR
DGS-3324SRi
DXS-3350SR
DGS-3612G
DGS-3627
DGS-3627G
DGS-3650
DXS-3326SR