Specifications
4. When defined as T, C, R or D, the value change is by pressing or to make the corresponding
M1840~M1871 ON (the client is required to write a plus/minus 1 program in the LADDER program) to achieve
this purpose.
Soft
key
0 1 2 3 4 5 6 7 8 9 T C D R
SHIFT
M1840 M1841 M1842 M1843 M1844 M1845 M1846 M1847 M1848 M1849 M1850 M1851 M1852 M1853 M1854 M1855
M1856 M1857 M1858 M1859 M1860 M1861 M1862 M1863 M1864 M1865 M1866 M1867 M1868 M1869 M1870 M1871
【Example】Assume definition as R0, defined as M0 mode 1 (Reset).
After entering 16 soft key mode in function 9,
Press
Display the address or DOC of R0, and then pressing , its corresponding
M1850 will be ON; OFF after it is released.
Display the address or DOC of M0 and force M0 OFF.
Note 1:After the 16 soft keys are defined, once function 9 is executed, it will enter 16 soft key operation mode
and then the 16 soft keys will be executed according to function 8 definition.
Note 2:In situation of
and with no definition, push either of them will cause DAP returning the
general data access function. Just push to turn back 8/16 soft keys mode.
Note 3:To return to normal operation mode, press〝
+ ( +++) +
〞.
Note 4:Push both
and at one time can transform 8/16 soft keys mode.
FUN 11(SET DAP NO.):Set DAP NO. for multi-link.
After any communication of FBs-PLC is converted to RS485 interface (Among which port2 as such is a
RS485 interface), the FBs-DAP-B(R) of the 16 sets can be connected. Each DAP shall need a unique number,
1~16 (but one of them must be number 1). This DAP is not related to PLC numbers, meaning the number can have
the same PLC number.
FUN 12(MAX. DAP NO. ON NETWORK): Set the max. DAP numbers on network for multi-link. (Max. 16 ,default 7)
In a connection of several DAPs, FBs-PLC can be joined with new DAPs. But the more the DAP number, the
longer the time to update information of each DAP. As a result, set the DAP number (the DAP number can not be
bigger than this number) on network appropriately will decrease time for information to update.
FUN 13(WRITE PROTECT):Data write-in protection
Aimed for monitored items (T, C, R, D, Y, M, S), set the information in write-in protection separately. Just fill
in the corresponding place with 1, and then the item is write-in protected and can be read values only.
FUN 14(RF CARD MODE):RF card mode selection
MODE=〝0〞
When reading a RF card, it will display whether this card is OK or Error. When the RF card is out
of sensing distance, it will pop up 〝NEXT〞, indicating another RF card is available now.
MODE=〝1〞 Once a RF card is read, it will beep once and will not display any information so the sensing
speed can be faster. But when many DAPs are connected, this mode will increase by about
60mS to each set for monitored item information.