User`s manual
CM-030PMCL-RH
27
Command Name
Format
Parameter
Remarks
3=EPS with Smear Less
2
Trigger Polarity
TP=[Param.]<CR><LF>
TP?<CR><LF>
0=Active Low
1=Active High
3
Trigger Input
TI=[Param.]<CR><LF>
TI? <CR><LF>
0=Camera Link
D -Image Format
1
Bit Allocation
BA=[Param.]<CR><LF>
BA?<CR><LF>
0=10bit
1=8bit
2
Scan Format
SC=[Param.]<CR><LF>
SC? <CR><LF>
0=Full Frame
1=2/3 Partial
2=1/2 Partial
3=1/4 Partial
4=1/8 Partial
3
V-Binning
VB=[Param.]<CR><LF>
VB?<CR><LF>
0=OFF
1=On
Only for CM-
030PMCL-RH
E - Gain, Black and signal settings
1
Gain Level
GA=[Param.]<CR><LF>
GA?<CR><LF>
-84 to 336
2
Black Level
BL=[Param.]<CR><LF>
BL?<CR><LF>
0 to 1023
F - Saving and loading data in EEPROM
1
Load Setttings
(from Camera
EEPROM)
LD=[Param.]<CR><LF>
0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area
Latest used DATA
AREA becomes
default at next
power up.
2
Save Settings
(to Camera
EEPROM)
SA=[Param.]<CR><LF>
1=User 1 area
2=User 2 area
3=User 3 area
Note : parameter 0 is not
allowed
3
EEPROM Current
Area No Request.
EA?<CR><LF>
0=Factory area
1=User 1 area
2=User 2 area
3=User 3 area
The camera
returns the latest
used DATA AREA.
NOTE: Do not try to use commands not shown in this list.