3. D12 Firmware update
Note:
A firmware update erases all user settings of the device. The device
name and the log files are kept.
The operating software firmware can be updated in two different
ways.
1. Firmware update of a single amplifier via serial interface using the
dbUpdate software program.
2. Firmware update of multiple amplifiers via the d&b Remote network
(CAN-Bus) using the R10 Service software.
In addition, the d&b Firmware Installer is required.
All required software packages can be downloaded from the d&b
website at
www.dbaudio.com.
3.1 Firmware Installer
The Firmware Installer is a software program used to archive the
firmware files for the d&b amplifiers to a desired directory on your
computer. During the update procedure these firmware files are
accessed either by D6-D12-dbUpdate or R10.
3.2 D12 Firmware update via D6-D12-dbUpdate
D6-D12-dbUpdate is a control software for loading new firmware and/
or loudspeaker setups onto the D12 Amplifier.
Fig. 9: SERVICE connector (D-SUB 9)
Fig. 10: 1:1 RS232 connection between
D12 and PC
To execute a firmware update the computer must be fitted with an
RS 232 interface (serial port) and a RS 232 extension cable must be
used (D-SUB 9 f/m cable with one to one connections between pins 2, 3
and 5).
Pin Signal Remark
2 RxD
3 TxD
4 DTR
5 GND Signal ground
7 RTS
Tab. 4: D-SUB 9 pin assignment on d&b devices
Please refer to the computer manual for the pin configuration of an
RS 232 port that uses a D-SUB 25 connector.
3.3 D12 Firmware update via CAN-Bus and R10
Using the d&b Remote network and the R10 Service software a
firmware update can be carried out via CAN-Bus. R10 allows to update
the firmware of multiple devices connected to the network at one time.
Notes:
For further information on R10 and the firmware update via CAN-Bus
please refer to the R10 manual.
A detailed description of remote control via CAN-Bus is given in the
technical information TI 312 (d&b code D5312.E.).
D12 Software manual (Firmware V2.x.x) (5.5 EN) Page 34 of 36