User manual

A1 front panel
OFF
ON
REM
PWR
TEMP
REM
PROT
LOCK
LO HI
(4.0 E) 2-5
2.2. A1 controls & indicators
PWR - Power (green)
On
. when the mainframe is connected to the mains supply, swit-
ched on and ready for use.
Off
. The mainframe is not connected to or powered from the
mains supply. The mains overvoltage protection has triggered
(see above) or the mainframe is not switched on.
Flashes
during the initial power-up cycle for about 2 seconds
and also when the mains overvoltage protection circuit is trigge-
red by an external fault (see also PROT below).
TEMP - Temperature (red)
Flashes
. The mainframe has switched off because the maximum
permissable operating temperature has been exceeded. This oc-
curs if the power amplifier heatsink temperature exceeds 83° C or
if the mains power transformer temperature exceeds 120° C.
PROT - Protect (red)
As the two mainframe power amplifier channels operate indepen-
dently there are separate PROT indicators for LO and HI channel.
On
. An internal fault has been detected on the mainframe chan-
nel concerned and that channel has been disconnected (e.g. DC
voltage fault in the output stage).
On and the PWR LED also flashes
. An external fault has
switched off the affected power amplifier channel. Typical faults
producing this indication are shorted speaker cables or a load
impedance which is too low for the amplifier to drive. Once the
cause of the fault has been identified and removed, either muting
and un-muting the controller module, or powering the mainframe
off and on again, will reset the mainframe fault protection circuits
and allow normal operation to resume.
REM - Remote (green)
On
. The mainframe is connected to the d&b RIB and ready for
communication.
LOCK (yellow)
On
. The mainframe has been placed in a locked condition by a
remote control system. This means that all the mainframe and
controller module controls with the exception of the mains switch
are inactive (locked out).
Off
. The A1 mainframe is set to local operation, i.e. may be ope-
rated using the front panel controls.
OFF/REM/ON (power switch)
OFF
. With the exception of the mains overvoltage protection cir-
cuit, the mainframe is isolated from the mains supply.
REM
. The mainframe is set to remote operation. If no remote
control system is connected this setting is equivalent to the power
switch OFF position.
ON
. The mainframe is switched on. In this switch position, the re-
mote control system can monitor and display the operational sta-
tus of the mainframe but cannot change any settings.