User manual

E18-SUB (1.1E)
E-PAC Configuration for
E18-SUB (E-PAC version 2)
E18
160Hz
GRISP
MUTE
OVL
-12 dB
-6 +6
0
Controls on E18
controller module
REMOTE
LO IMP
DELAY ON
CUT
HFA
SPKR
21 3456 87
ON
Operation with P1200A
Up to two E18-SUBs can be driven by each P1200A power
amplifier channel. Fitting one E18-SUB-CO and one C or E-Series
TOP controller module allows a single mainframe to drive two
E18-SUB and two (E3: four) mid/high cabinets. All cabinets can be
linked together locally and fed by a single four-wire cable from
either mainframe output connector.
E18 Controller module switches
160Hz switch and indicator
If the 160Hz switch is selected (yellow 160Hz LED illuminated), the
upper operating frequency of the system is raised from 110 Hz to
160 Hz. This setting can be used when E18-SUBs are used with the
C6 system - the 160Hz setting on the C6-CO should also be
selected to increase the C6 system's headroom (see C6 data
sheet).
Operation with E-PAC
To drive E18-SUB cabinets the E-PAC has to be configured to E18
mode by setting the appropriate DIP switches on the rear panel
(only possible with E-PAC version 2).
The E-PAC can drive a single E18-SUB at an output power of 300
watts. Connecting a second E18-SUB requires LO IMP mode to be
selected on the E-PAC rear panel. Due to the 6 dB reduction of input
level to the speakers in low impedance mode there is no gain in
acoustical output.
DIP switches 1 and 2 (CUT and HFA) are not functional with the
configuration E18-SUB.
The 160Hz mode of the E18 controller module is not available on
the E-PAC controller.