User manual

2-12 E-PAC (V02) User Manual
E-PAC (V02) object addresses for remote operation with the d&b RIB
Address
Read/
Write Object Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 RD Status Base Device Gnrl-Error SW-Rem LockCmd LockMode PWR Ok PWR On
0 WR Status Base Device LockCmd PWR On
1 RD/WR Switch Settings 2 DELAY ON
2 RD/WR Potentiometer Attenuation in steps of 0.5dB, 7-bit coded (0=+6dB, 127=–57.5dB)
3 RD/WR Switch Settings 1 MUTE Switch 5 LO IMP Switch 4 Switch 3 HFA CUT
6 RD/WR Delay time coarse Delay in steps of 10 ms, 7-bit coded (max. 17 = 170 ms)
7 RD/WR Delay time fine Delay in steps of 0.1 ms, 7-bit coded (max. 127 =12.7 ms)
8 RD Errors Base Device Tmp Error Tmp Warn AMP Protect AMP Error
10 RD Output Signal Present
12 RD LED's Controller ISP GR OVL
13 RD Headroom/GainRed 0..63:Headroom, 64..127:GainRed, 7-bit coded (0=32dB Hdrm, 64=0dB, 127=31.5dB GR)
2.14. REMOTE addressing
The basic structure of the E-PAC object addresses in the d&b RIB is
identical to the A1 (LO channel) or P1200A (channel A) addresses.
Compared with Version 1, the E-PAC Version 2 has an extended
functionality (programmable delay and additional system
configurations).
All Version 1 functions and object addresses are retained
unchanged on Version 2. Thus an E-PAC Version 2 can be
operated with a RIB/ROPE control, which was set up for E-PAC
Version 1.