User manual

2-10 E-PAC (V02) User Manual
IMPORTANT!
ISP
ERR
O
+6–6
–12
E-PAC
190 [7.48"]
331 [13.03"]
E-PAC enclosure dimensions in mm [inch]
E-PAC enclosure dimensions with rack mount kit in mm [inch]
ISP
ERR
O
+6–6
–12
E-PAC
ISP
ERR
O
+6–6
–1 2
E-PAC
338 [13.31"]
483 [19.00"]
465 [18.30"]
352 [13.86"]
The E-PAC enclosure can get hot during operation, therefore allow
an air gap of at least 2 cm (3/4") between an E-PAC and the rack
top/bottom panels, or other equipment above or below. This is
not necessary between adjacent E-PACs.
When installing E-PACs always allow sufficient free air flow
around the enclosure and never block or cover the rear panel air
intake vent or the front panel air outlet vent. If E-PACs are to be
installed in sealed equipment racks, then additional fan modules
will be needed. The E-PAC air intake is at its rear panel; therefore
external fans should supply air to the inside of the rack.
2.12. Dimensions